Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers from the Neubrandenburg Conference, 8-9 June, 2018
Article type: Research Article
Authors: Gerk, U.a; * | Franke, R.P.b | Krüger-Genge, A.c; d | Jung, F.e
Affiliations: [a] Städtisches Klinikum Dresden, II. Medizinische Klinik, Dresden, Germany | [b] Department of Biomaterials, Central Institute for Biomedical Technology, University of Ulm, Ulm, Germany | [c] Department of Anesthesia, Pain Management and Perioperative Medicine, Faculty of Medicine, Dalhousie University, Halifax, Canada | [d] Fraunhofer Institute Applied Polymer Research (IAP), Division of Life Science and Bioprocesses, Department of Biomaterials and Healthcare, Potsdam-Golm, Germany | [e] Institute of Clinical Haemostasiology and Transfusion Medicine, University of Saarland, Homburg, Germany
Correspondence: [*] Corresponding author: U. Gerk, Krankenhaus Dresden-Friedrichstadt, II. Medizinische Klinik, Dresden, Germany. E-mail: ulrich.gerk@klinikum-dresden.de.
Abstract: BACKGROUND: Contrast-induced acute kidney injury (CI-AKI), a potentially life-threatening complication of iodinated contrast media in patients with impaired renal function, has attracted increasing attention in recent years. There is overwhelming evidence that the most important pre-disposing factor for a contrast-medium induced nephropathy is the pre-existence of a renal impairment. METHODS: The registry was performed as a part of a quality management project in the Dresden-Friedrichstadt heart catheter laboratory. In compliance with the Declaration of Helsinki/Somerset West, 9,026 patients were included between 2010 and 2015. 100 patients of these were participants in a chronic dialysis program. All patients were dialyzed on the day before angiography. In all patients a coronary angiography, in 28 patients a stent implantation and in 12 patients a surgical reconstruction had to be performed. Prior to the intervention and one, two and three days thereafter the serum creatinine was measured. RESULTS: Up to the third day after application of the iodinated contrast medium no significant changes of the serum creatinine (baseline value: 423.3±42.6μmol/l) occurred (ANOVA for repeated measures: p = 0.507). On average, a slight decrease of the serum creatinine was found.All patients remained in their routine dialysis-program. 18 out of 100 died during the next three months after the procedure. CONCLUSION: The study revealed that the coronary angiography using Iodixanol as iodinated contrast medium did not result in an increase of serum creatinine, which was drastically elevated in these patients before application of the iodinated contrast medium.
Keywords: Keywords: Iodixanol, renal insufficiency, dialysis, serum creatinine
DOI: 10.3233/CH-189304
Journal: Clinical Hemorheology and Microcirculation, vol. 70, no. 4, pp. 391-398, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl