Article type: Research Article
Authors: Li, Xiang; 1 | Hou, Xiu-Juan; 1 | Du, Lin-Yao | Wu, Jia-Qi | Wang, Luo | Wang, Hong | Zhou, Xian-Li; *
Affiliations: In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
Correspondence: [*] Corresponding author: Xian-Li Zhou, In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Surgeon’s Hall, No. 246, Xuefu Road, Nangang District, Harbin City, Heilongjiang, China. Tel.: +86 0451 86297285; E-mail: zhouxianli@ems.hrbmu.edu.cn.
Note: [1] These authors contributed equally to this work
Abstract: OBJECTIVE:This study was conducted to investigate the diagnostic performance of Virtual Touch Tissue Imaging and Quantification (VTIQ), combined with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) in differentiating malignant and benign thyroid nodules. METHODS:A total of 130 thyroid nodules in 128 patients were included. The diagnostic performance of conventional ultrasound (US), VTIQ, and the combination of these two techniques was calculated and compared according to the area under the receiver operating characteristic curve (AUROC), for sensitivity, specificity, and accuracy. RESULTS:The sensitivity and specificity for the ACR TI-RADS were 98.6% (72/73) and 24.6% (14/57), respectively. There was a strong agreement with ACR TI-RADS categories of thyroid nodules (all ICCs > 0.60). With an optimal cutoff value of 2.46 m/s, the sensitivity and specificity of the minimal shear wave velocity (SWVmin) were 87.7% (64/73) and 70.2% (40/57). By applying this value to downgrade or upgrade ACR TI-RADS, the specificity significantly increased from 24.6% (14/57) to 47.4% (27/57; P < 0.05) and the sensitivity remained at 98.6% (72/73). CONCLUSIONS:VTIQ combined with ACR TI-RADS could improve the specificity of the differential diagnosis of thyroid nodules without a loss of sensitivity.
Keywords: Ultrasound, elastography, thyroid nodule, thyroid imaging reporting and data system, virtual touch tissue imaging and quantification
DOI: 10.3233/CH-180477
Journal: Clinical Hemorheology and Microcirculation, vol. 72, no. 3, pp. 279-291, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl