Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liu, Shui-Qinga; b | Liu, Yan-Pingb | Zhou, Bang-Guob; * | Deng, Xiao-Honga; c | Li, Xiao-Longa | Xiang, Li-Huaa | Ren, Wei-Weia | Xu, Hui-Xionga; *
Affiliations: [a] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China | [b] Department of Medical Ultrasound, Changzhou First People’s Hospital and The Third Affiliated Hospital of Suzhou University, Changzhou, China | [c] Department of Medical Ultrasound, Fujian Cancer Hospital and Fujian Medical University Cancer Hospital, Fuzhou, China
Correspondence: [*] Corresponding authors: Hui-Xiong Xu, MD, PhD and Bang-Guo Zhou, MD, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai 200072, China. Tel.: +86 21 66307539; E-mails: xuhuixiong@126.com (H.-X. Xu) and 913565417@qq.com (B.-G. Zhou).
Abstract: OBJECTIVE:To determine the diagnostic performance of conventional ultrasound (US) and two-dimensional shear wave elastography (2D SWE) in the differential diagnosis between mastitis and breast malignancy. METHODS:Between January 2016 and March 2017, 105 patients with 105 pathologically proven breast lesions were enrolled. All the lesions were subject to conventional US and 2D SWE examinations. In 2D SWE, the qualitative parameter of stiff rim sign and quantitative parameter of maximal shear wave velocity (SWV) were obtained. The diagnosis performances of US and combination of US and 2D SWE were evaluated, including sensitivity, specificity and the area under the receiver operating characteristic curve (AUROC). The AUROC of US and the combined method were also evaluated in subgroups with different diameters. RESULTS:Pathologically, 26 breast lesions were confirmed to be mastitis and 79 were malignant. The cut-off value for maximal SWV was 6.75 m/sec. The AUROC of stiff rim sign and maximal SWV were 0.701 (95% CI: 0.587–0.815) and 0.753 (95% CI: 0.659–0.832) respectively. Compared with US, the specificity and AUROC of the combined method increased significantly (specificity: 11.5% vs. 96.1%, AUROC: 0.520 vs. 0.752; both P < 0.05). CONCLUSIONS:The combination of US and 2D SWE improved the diagnostic performance in the differential diagnosis between mastitis and breast malignancy in comparison with the conventional US alone.
Keywords: Shear wave elastography, conventional ultrasound, mastitis, breast malignancy
DOI: 10.3233/CH-180400
Journal: Clinical Hemorheology and Microcirculation, vol. 70, no. 3, pp. 347-354, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl