Abstract: PURPOSE:To compare the diagnostic performance of real-time maximum liver capacity (LiMAx) with dynamic contrast-enhanced ultrasound (CEUS)-based liver microcirculation. MATERIALS AND METHODS:23 patients underwent liver function capacity (LiMAx) test and consecutive or previous CEUS examinations. A bolus injection of 1.4 ml sulfur hexafluoride microbubbles was administered for CEUS measurements (1–6 MHz) and quantitative perfusion analysis (TIC) was performed with an integrated perfusion software using stored cine-loops. Two perfusion-parameters, time to peak (TtoP) and area under the curve (Area), were evaluated in liver parenchyma and portal vein using TIC analysis.To compare quantification parameters, patients were classified in patients representing a healthy population (LiMAx value >315 μg/kg/h) and those representing patients with liver disease (LiMAx value <315 μg/kg/h). RESULTS:Comparing perfusion parameters derived from portal vein measurements, TtoP and Area were higher in patients with normal liver function TtoP: 25.0±8.4 s, Area: 1483±920 a.u. compared to patients with impaired liver function TtoP: 22.4±14.0 s; Area 1351±1212 a.u. This difference however was not statistically significant (p = 0.52, p = 0.48).In parameters derived from measurements in liver parenchyma TtoP was higher (38.5±11.3 s) and Area was lower (999±632 a.u.) in patients with normal liver function compared to patients with impaired liver function (TtoP; 30.6±11.0 s, p = 0.156; Area: 1202±719 a.u.) (p = 0.16, p = 0.56).In a simple linear regression model, none of the perfusion parameters measured in portal vein (TtoP portal, Area portal) and liver parenchyma (TtoP liver, Area liver) correlated significantly with respective LiMAx values (p = 0.194–0.950). CONCLUSION:Within the framework of this study, CEUS-based perfusion parameters were not able to assess severity of liver disease, assessed with LiMAx- test.
Keywords: Liver capacity, LiMAx, CEUS, microcirculation, liver function
DOI: 10.3233/CH-179217
Journal: Clinical Hemorheology and Microcirculation, vol. 67, no. 3-4, pp. 373-382, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl