Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles of the 32nd Annual Conference of the German Society for Clinical Hemorheology and Microcirculation, Dresden, Germany, 24 – 25 May, 2013
Article type: Research Article
Authors: Jung, F. | Leithäuser, B. | Landgraf, H. | Jünger, M. | Franzeck, U. | Pries, A. | Sternitzky, R. | Franke, R.P. | Forconi, S. | Ehrly, A.M.
Affiliations: Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies, Helmholtz-Zentrum Geesthacht, Teltow, Germany | Department of Cardiology/Angiology, Asklepios Clinic Hamburg, Hamburg, Germany | Zentrum für Gefäßmedizin, Klinikum Friedrichshain, Berlin, Germany | Department of Dermatology, Ernst-Moritz-Arndt-University, Greifswald, Germany | Zentrum für Gefäßkrankheiten, Zürich, Schweiz | Department of Physiology, Charité - Universitätsmedizin Berlin, Berlin, Germany | Praxisklinik Herz – Gefäße, Dresden, Germany | Department of Biomaterials, University of Ulm, Ulm, Germany | Department of Internal Medicine, University of Siena, Siena, Italy | Department of Angiology, Johann-Wolfgang Goethe University, Frankfurt, Germany
Note: [] Corresponding author: Prof. Dr. F. Jung, Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies, Helmholtz-Zentrum Geesthacht, Teltow, Germany. E-mail: friedrich.jung@hzg.de
Abstract: Back scattered Laser Doppler (LD) signals are composed of two different individual signals. The number of the moving particles and the speed of the particles in the measured tissue volume determine the frequency shift and the band width of the Doppler signal. The dependence of the Laser Doppler flux on the number of scattering particles is highly nonlinear: at very low hematocrit and high speed the axial migration of the cells to the centre of the blood vessels is very strong, so that in these cases – because of the parabolic flow profile - the Doppler flux measurement overestimates the mean real blood flow (up to two- or three-fold). The opposite is the case when the hematocrit is very high, then the blood flow might be underestimated (due to the increased amounts of blood cells near the vessel wall). In addition, a very change in number of moving particles - as can occur during the postprandial phase or during therapy - can change the signal also at a constant cell number. Also, it must be mentioned that the LD signal possibly is not only reflected by moving blood cells in the different skin layers but also by blood cells flowing in tissues below the skin (particularly below atrophied skin areas of older patients) so that in such cases the LD Flux signal reflects not exclusively the skin blood flow. Therefore, LD flux at rest may still be within the normal range even in advanced states of disease, since the scattered light is sampled from a tissue volume which may contain also non-nutritive shunt vessels. This critical analysis of the LD signals of course shall not lead to an overall rejection of the application of laser Doppler systems. Actual progress only can, however, be obtained under the exact consideration of anatomical conditions, technical restrictions and when generalizations are avoided.
Keywords: Microcirculation, laser doppler measurements, cutaneous
DOI: 10.3233/CH-131778
Journal: Clinical Hemorheology and Microcirculation, vol. 55, no. 4, pp. 411-416, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl