Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kim, Jeeyonga | Cho, Chi Hyuna | Jung, Bo Kyeunga | Nam, Jeonghuna | Seo, Hong Seogb; 1; * | Shin, Sehyunc | Lim, Chae Seunga; 1; *
Affiliations: [a] Department of Laboratory Medicine, College of Medicine, Korea University, Seoul, Republic of Korea | [b] Department of Internal Medicine, Division of Cardiology, College of Medicine, Korea University, Seoul, Korea | [c] School of Mechanical Engineering, Korea University, Seoul, Korea
Correspondence: [*] Corresponding authors. Chae Seung Lim, MD, Department of Laboratory Medicine, Guro Hospital, Korea University College of Medicine, 148 Guro Dong Ro, Guro Gu, Seoul 08308, Korea. Tel.: +82 2 2626 3245; Fax: +82 2 2626 1465; E-mail: malarim@korea.ac.kr and Hong Seog Seo, MD, Division of Cardiology, Department of Medicine, Guro Hospital, Korea University College of Medicine, Guro 2 Dong, Guro Gu, Seoul 152-703, Korea, Tel.: +82 2 2626 3018; Fax: +82 2 2626 1069; E-mail: mdhsseo@korea.ac.kr.
Note: [1] These corresponding authors contributed equally to this work.
Abstract: The objective of this study was to comparatively evaluate three commercial whole-blood platelet function analyzer systems: Platelet Function Analyzer-200 (PFA; Siemens Canada, Mississauga, Ontario, Canada), Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), and Plateletworks Combo-25 kit (PLW; Helena Laboratories, Beaumont, TX, USA). Venipuncture was performed on 160 patients who visited a department of cardiology. Pairwise agreement among the three platelet function assays was assessed using Cohen’s kappa coefficient and percent agreement within the reference limit. Kappa values with the same agonists were poor between PFA-collagen (COL; agonist)/adenosine diphosphate (ADP) and MP-ADP (–0.147), PFA-COL/ADP and PLW-ADP (0.089), MP-ADP and PLW-ADP (0.039), PFA-COL/ADP and MP-COL (–0.039), and between PFA-COL/ADP and PLW-COL (–0.067). Nonetheless, kappa values for the same assay principle with a different agonist were slightly higher between PFA-COL/ADP and PFA-COL/EPI (0.352), MP-ADP and MP-COL (0.235), and between PLW-ADP and PLW-COL (0.247). The range of percent agreement values was 38.7% to 73.8%. Therefore, various measurements of platelet function by more than one method were needed to obtain a reliable interpretation of platelet function considering low kappa coefficient and modest percent agreement rates among 3 different platelet function tests.
Keywords: Multiplate analyzer, Platelet function analyzer-200, Plateletworks
DOI: 10.3233/CH-170331
Journal: Clinical Hemorheology and Microcirculation, vol. 70, no. 3, pp. 257-265, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl