Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles of the 14th International Congress of Biorheology and the 7th International Conference of Clinical Hemorheology, July 4–7, 2012, Istanbul, Turkey
Article type: Research Article
Authors: Baskurt, Oguz K. | Meiselman, Herbert J.
Affiliations: Koç University School of Medicine, Istanbul, Turkey | Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
Note: [] Corresponding author: Herbert J. Meiselman, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA. E-mail: hmeiselman@gmail.com
Abstract: Red blood cells (RBC) are exposed to various levels of shear stress (SS) during their flow in the circulatory system, yet no significant damage occurs if their mechanical stability is not impaired. Alternatively, normal RBC may be damaged during flow in non-physiological environments and under extreme SS (e.g., extracorporeal circulation, ventricular assist devices). The shear-induced damage may result in hemolysis or in altered mechanical properties of RBC that, in turn, reduces the ability of RBC to withstand further damage by SS. An ektacytometer employing a Couette shearing system was used to apply SS at a constant level of 100 Pa for 300 seconds as a model of sub-hemolytic mechanical stress. The degree of cellular damage during and after the application was assessed by diffraction pattern analysis. The area of the diffraction pattern was found to correlate with the number of RBC in the sheared suspension. Monitoring the ellipse area during the application of gradually increasing SS provides the concentration of the remaining intact RBC and can therefore be used to estimate the hemolytic threshold as a measure of RBC mechanical stability. The hemolytic threshold determined after the mechanical stress application was found to be ~150 Pa, while it was ~250 Pa in the same samples before the SS application. Additionally, SS-elongation index curves recorded before and after the application of the sub-hemolytic SS significantly differed from each other, indicating the impairment in deformability following the mechanical stress. The Couette type ektacytometer can be used as a tool to assess the sub-hemolytic damage to RBC in testing the biomedical equipment.
Keywords: Erythrocyte mechanical stability, artificial organs, left ventricular assist device, ektacytometry, hemolyic threshold
DOI: 10.3233/CH-131689
Journal: Clinical Hemorheology and Microcirculation, vol. 55, no. 1, pp. 55-62, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl