Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Presentations held at the 35th Conference of the German Society for Clinical Microcirculation and Hemorheology, Mainz, Germany, 4-5 November, 2016
Guest editors: F. Jung and T. Gori
Article type: Research Article
Authors: Lamby, P.a; * | Jung, F.b | Falter, J.a | Mrowietz, C.c | Graf, S.a | Schellenberg, L.d | Platz Batista da Silva, N.e | Prantl, L.a | Franke, R.P.f | Jung, E.M.d
Affiliations: [a] Department of Plastic and Reconstructive Surgery, University Hospital Regensburg, Regensburg, Germany | [b] Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies, Helmholtz-Zentrum Geesthacht, Teltow, Germany | [c] Institute for Heart and Circulation Research, Eißendorfer Pferdeweg, Hamburg-Harburg, Germany | [d] Department of Anesthesiology, University of Regensburg, Regensburg, Germany | [e] Department of Radiology, University Hospital Regensburg, Regensburg, Germany | [f] Department of Biomaterials, Central Institute for Biomedical Engineering, University of Ulm, Ulm, Germany
Correspondence: [*] Corresponding author: P. Lamby, Department of Plastic and Reconstructive Surgery, University Hospital Regensburg, Regensburg, Germany. Tel.: +49 941 944 6763; Fax: +49 941 944 6948; E-mails: philipp@lamby.org; philipp.lamby@klinik.uni-regensburg.de.
Abstract: BACKGROUND: Intra-arterial administration of radiographic contrast media (CM) is discussed to impair renal perfusion. The pathogenesis of contrast-induced Nephropathy (CIN) is still not clarified. OBJECTIVE: This trial was performed to prove the effects of two CM with different molecular structure on renal perfusion. METHODS: A prospective, randomized study on 16 pigs was designed to compare the outcome after application of a low-osmolar iodinated CM (770 mOsm/kg H2O – Group1) and an iso-osmolar iodinated CM (290 mOsm/kg H2o – Group2). Color Coded Doppler Sonography (LOGIQ E9, GE, Milwaukee, USA) was applied for measuring the Renal Resistive Index (RRI) before and after the first, fifth, and tenth bolus of CM. Statistics was performed using analysis of variance for repeated measurements with the Factor “CM”. RESULTS: All flow spectra were documented free of artifacts and Peak Systolic Velocity (PSV), Enddiastolic Velocity (EDV) and RRI respectively could be calculated. Mean PSV in Group 1 led to a decrease while in Group 2 PSV showed a significant increase after CM (p = 0,042). The course of the mean EDV in both groups deferred accordingly (p = 0,033). Mean RRI over time significantly deferred in both groups (p = 0,001). It showed a biphasic course in Group 2 and a decrease over time in Group 2. CONCLUSION: While iso-osmolar CM induced an increase of PSV and EDV together with a decrease of RRI, low-osmolar CM could not show this effect or rather led to the opposite.
Keywords: Renal perfusion, radiographic contrast media, contrast agent, CCDS, color coded Doppler sonography, contrast-induced Nephropathy, CIN
DOI: 10.3233/CH-168110
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 3, pp. 287-295, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl