Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers of the 31st Conference of the German Society for Clinical Microcirculation and Hemorheology, Halle, Germany, 15–16 June 2012
Article type: Research Article
Authors: Braune, S. | Alagöz, G. | Seifert, B. | Lendlein, A. | Jung, F.
Affiliations: Centre for Biomaterial Development and Berlin-Brandenburg Center for Regenerative Therapies (BCRT), Institute of Polymer Research, Helmholtz-Zentrum Geesthacht, Teltow, Germany
Note: [] Corresponding author: A. Lendlein, Centre for Biomaterial Development and Berlin-Brandenburg Center for Regenerative Therapies (BCRT), Institute of Polymer Research, Helmholtz-Zentrum Geesthacht, Kantstr. 55, 14513 Teltow, Germany. Tel.: +49 03328 352 450; Fax: +49 03328 352 452; E-mail: andreas.lendlein@hzg.de
Abstract: A dataset of 439 confocal laser scanning microscopic images was analyzed to investigate the potential of an image-based automated analysis for identifying and assessing adherent thrombocytes on polymer surfaces. Parameters for image optimization of glutardialdehyde induced fluorescence images were classified and data mining was performed using the Java image processing software ImageJ. Previously reported analysis required that each thrombocyte had to be identified interactively and outlined manually. Now, we were able to determine the number and area of adherent thrombocytes with high accuracy (spearman correlation coefficient r = 0.98 and r = 0.99) using a two-stage filter-set, including a rolling ball background subtraction- and a watershed segmentation-algorithm. Furthermore, we could proof a significant correlation between these parameters (spearman correlation coefficient r = 0.97), determining both as suitable predictors for the evaluation of material induced thrombogenicity. The here reported image-based automated analysis can be successfully applied to identify and measure adherent thrombocytes on polymer surfaces and, thus, might be successfully integrated in a high-throughput screening process to evaluate biomaterial hemocompatibility.
Keywords: Hemocompatibility, thrombocytes, biomaterial, high-throughput, image-based automation
DOI: 10.3233/CH-2012-1610
Journal: Clinical Hemorheology and Microcirculation, vol. 52, no. 2-4, pp. 349-355, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl