Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers of the 31st Conference of the German Society for Clinical Microcirculation and Hemorheology, Halle, Germany, 15–16 June 2012
Article type: Research Article
Authors: Mueller, S. | Gosau, M. | Wendl, C.M. | Prantl, L. | Wiggermann, P. | Reichert, T.E. | Jung, E.M.
Affiliations: Department of Cranio-Maxillofacial Surgery, University Medical Center Regensburg, Regensburg, Germany | Institute of Radiology, University Medical Center Regensburg, Regensburg, Germany | Department of Plastic Surgery, University Medical Center Regensburg, Regensburg, Germany
Note: [] Corresponding author: Steffen Mueller, MD, DMD, Department of Cranio-Maxillofacial Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany. E-mail: steffen.mueller@klinik.uni-regensburg.de
Abstract: Purpose: Quantitative measurement of dynamic contrast values obtained by contrast-enhanced ultrasound (CEUS) for evaluating microvascularization in osseous and osseocutaneous free flaps used for maxillofacial reconstructions. Patients and Methods: 22 patients (6 women, 16 men, mean age: 57 years, range: 47 to 82 years) who had received mandibular reconstructions with 3 avascular and 19 microvascular free osseous or osseocutaneous transplants were included in this trial. 16 patients had received a microvascular osseocutaneous fibular flap, 2 patients a microvascular osseous fibular flap and 1 patient a microvascular osseous iliac crest flap. Patients were followed up for 12 months on average (range: 3 to 20 months). Ultrasound examination was carried out by one experienced examiner with a linear probe (6–9 MHz, LOGIQ E9, GE) after the intravenous bolus injection of 2.4 ml contrast agent (SonoVue®, BRACCO, Germany). Digital cine loops were analysed with a quantification software (VueBox™) for determining wash-in parameters: Rise Time (RT), Peak Enhancement (PE), Wash-in Area Under the Curve (WiAUC) and Wash-in Rate (WiR). Results were compared with the patients' postoperative clinical outcome. Results: For the bone area the median of the RT was 10.0 s (range 3.1 to 65.0 s), for the ratio between bone tissue and soft tissue for the PE the median was 10.4% (range 2.6 to 29.8%), the median for the WiAUC was 11.1% (range 1.5 to 77.7%) and the median for the WiR was 5.7 %(range 0.7 to 61.1%). None of the patients with microvascular osseocutaneous and osseous flaps showed any signs of transplant bone loss, which corresponded with the qualitative CEUS assessment. The patients with microvascular re-anastomosed transplants showed widely varying values for the investigated parameters (RT, PE, WiAUC, WiR). For patients with avascular bone transplants, these parameters were reduced to zero values for the bone area resulting in a significant difference (p < 0.05) for the PE compared to the patients with microvascular bone transplants. Conclusion: CEUS allowed the qualitative assessment of bone microvascularization by observing the transition of the contrast agent from the periostal area into the bone. However, defining a critical lower border by quantification of bone perfusion was difficult because of the inconstant perfusion of the bone transplants used in the trial.
Keywords: Osseous flaps, osseocutaneous flaps, contrast-enhanced ultrasound, perfusion quantification
DOI: 10.3233/CH-2012-1596
Journal: Clinical Hemorheology and Microcirculation, vol. 52, no. 2-4, pp. 187-196, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl