Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers of the 31st Conference of the German Society for Clinical Microcirculation and Hemorheology, Halle, Germany, 15–16 June 2012
Article type: Research Article
Authors: Niehues, S.M. | Müller, C. | Plendl, J. | Richardson, K.C. | Gemeinhardt, O. | Hünigen, H. | Unger, J.K. | Jung, F. | Hamm, B. | Hiebl, B.
Affiliations: Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany | Department of Veterinary Medicine, Institute of Veterinary Anatomy, Freie Universität Berlin, Berlin, Germany | School of Veterinary and Biomedical Sciences, Murdoch University, Murdoch, WA, Australia | Department of Experimental Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany | Department for Clinical Haemostaseology and Transfusion Medicine, Faculty of Medicine, Saarland University, Homburg/Saar, Germany | Faculty of Medicine, Center for Medical Basic Research, Martin-Luther-University Halle-Wittenberg, Halle, Germany
Note: [] Corresponding author: B. Hiebl, Faculty of Medicine, Center for Medical Basic Research, Martin-Luther-University Halle-Wittenberg, Magdeburger Strasse 18, 06112 Halle, Germany. E-mail: bernhard.hiebl@medizin.uni-halle.de
Abstract: Minipigs are frequently used for scientific research as they are easy to handle and the dimensions of their vascular system do not change after 20 months of age. Although surgical interventions under anaesthesia are often performed in the supine position the effects of this positioning on lung functionality in minipigs have not been systematically described. This study aimed to analyse the influence of supine positioning on the macrostructure of the lung and the pulmonary density by the use of computed tomography imaging in pre-adult Göttingen minipigs. Twelve pre-adult female minipigs were used in the study and lung density was investigated in both the prone and the supine positions. The time between the scans in prone and supine positions was less than 5 minutes (296 ± 6 sec). In the prone position lung density did not differ between the dorsal and ventral part of the lung (−641 ± 72 Hounsfield units [HU]). However in the supine position there was a ventrodorsal gradient of decreasing density (ventral part of the lung: −497 ± 106 HU, dorsal part of the lung: −723 ± 51 HU). The changes in lung density were not accompanied by changes in lung volume (829 ± 191 ml). These results suggest an influence of the body position on the ventilation/perfusion ($\dot{V}_A/\!\dot{Q}$) matching of the lung which could possibly result in lowered lung oxygenation as well as in an increased heart activity in the supine position. Additionally, due to the steep course of the vena cava caudalis from the caval foramen in the diaphragm across to the heart (in contrast to the more shallow course in the prone position) the activity of the heart necessary to pump the venous blood to the right atrium has to be higher in the supine position than in the prone position. In pigs the capacity of the heart to increase frequency is limited due to a diastolic/systolic (D/S) ratio <1. Supine positioning may possibly increase their risk of cardiovascular complications.
Keywords: Computed tomography, minipigs, lung density, positioning, perfusion
DOI: 10.3233/CH-2012-1586
Journal: Clinical Hemorheology and Microcirculation, vol. 52, no. 2-4, pp. 85-92, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl