Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Proceedings of the 16th Conference of the European Society for Clinical Hemorheology and Microcirculation (ESCHM), 18–21 June, 2011, Munich, Germany
Article type: Research Article
Authors: Papp, J. | Toth, A. | Sandor, B. | Kiss, R. | Rabai, M.; | Kenyeres, P. | Juricskay, I. | Kesmarky, G. | Szabados, S. | Toth, K.
Affiliations: 1st Department of Medicine, University of Pecs, School of Medicine, Pecs, Hungary | Heart Institute, University of Pecs, School of Medicine, Pecs, Hungary | Department of Physiology and Biophysics, University of Southern California, Keck School of Medicine, Los Angeles, CA, USA
Note: [] Corresponding author: Prof. Kalman Toth, MD, ScD, FESC, 1st Department of Medicine, University of Pecs, School of Medicine, 7623 Pecs, Rakoczi ut 2., Hungary. Tel.: +36 72 536145; Fax: +36 72 533113; E-mail: kalman.toth@aok.pte.hu
Abstract: Conditions during coronary artery bypass grafting (CABG) performed on beating heart (off-pump) are more physiological than using extracorporeal perfusion (on-pump). The present study aims to examine the hemorheological aspects of the two techniques. Blood samples were taken from patients undergoing on-pump (n = 25) and off-pump (n = 22) CABG, upon arrival to the operating theatre, after 20 and 40 minutes during the operation, after closing the thorax, on the 1st and 2nd postoperative days, and during the 2nd and 6th month control check-ups. Hematocrit (Hct), plasma and whole blood viscosity (PV, WBV; Hevimet 40 capillary viscometer), red blood cell (RBC) aggregation (Myrenne RBC aggregometer, LORCA) and deformability (LORCA, Carat FT-1 filtrometer), and platelet aggregation (Carat TX4 aggregometer) were determined. The morphology of red blood cells was investigated by scanning electron microscopy (SEM). Hct, PV, WBV and RBC aggregation decreased significantly during the early phase of the surgery, they started to recover during the postoperative period, and reached the baseline values by the 2nd and 6th month control check-ups. These parameters were significantly lower in samples taken after 20 and 40 minutes in the on-pump group. SEM showed rather damaged and malformed cells in case of on-pump surgery. Ektacytometry showed no significant difference, but RBC deformability was impaired during on-pump surgery when measured by filtrometry. The decrease in platelet aggregation was more pronounced by the end of surgery in case of on-pump technique. During CABG rheological parameters change less when using the off-pump method, and mechanical damage of RBCs are also smaller. The off-pump technique seems to be favorable from a hemorhelogical point of view.
Keywords: Coronary artery bypass grafting, on-pump, off-pump, viscosity, erythrocyte aggregation, erythrocyte deformability, platelet aggregation, scanning electron microscopy
DOI: 10.3233/CH-2011-1484
Journal: Clinical Hemorheology and Microcirculation, vol. 49, no. 1-4, pp. 331-346, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl