Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chabanel, Anne | Samama, Meyer M.
Affiliations: Laboratoire Central d'Hématologie, Hôpital Hôtel-Dieu, Paris, France
Abstract: Several methods are presently used to evaluate plasma viscosity and its variation. The falling ball viscometer, in spite of its cheap running cost, has been only used by a limited number of laboratories. We wish in this article to give our own appraisal of the technique. We studied the influence of the individual glass syringes and stainless steel balls, as well as the temperature dependence on plasma viscosity value. Freezing plasma samples did not appear to affect the value of plasma viscosity, as well as the mode and frequency of thawing, since the variations (0.01 mPa.s or less) were equivalent to the reliance of the technique (0.01 mPa.s, 1%). A reference range for healthy controls was determined. We could not detect any significant difference between men and women for plasma viscosity values. In spite of the fibrinogen increase with aging or smoking, we could not observe any significant variation for plasma viscosity values in healthy controls. However, in a large range of fibrinogen values, a good correlation was found between plasma viscosity and fibrinogen concentration (r2 = 0.460; p = 0.0001). In 9 patients with IgG myeloma, a significant correlation between serum viscosity and IgG concentration was obtained (r2 = 0.797; P = 0.001). Concomittant measurements of plasma viscosity with a rotational viscometer (Contraves LS30) showed a strong correlation with our values (r2 = 0.980). We conclude that falling ball viscometry is a valid technique to measure plasma viscosity variations in clinical or research studies.
Keywords: plasma viscosity, viscometer, fibrinogen, age, smoking, paraproteinemia
DOI: 10.3233/CH-1994-14310
Journal: Clinical Hemorheology and Microcirculation, vol. 14, no. 3, pp. 401-412, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl