Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ginsbourg, Shay; | Levin, Shlomo | Einav, Shmuel; | Korenstein, Rafi
Affiliations: Department of Physiology and Pharmacology, Tel Aviv University, Tel Aviv, Israel | Department of Bioengineering, Tel Aviv University, Tel Aviv, Israel
Note: [] Corresponding author: Prof. Shmuel Einav, Department of Biomedical Engineering, Tel Aviv University, Tel Aviv 69978, Israel. Tel.: +972 3 6409418; Fax: +972 3 6409448; Cell: +972 544 750433; E-mail: einav@eng.tau.ac.il; URL: http://www.tau.ac.il/~einav.
Abstract: In this study, the human RBC capillary flow has been modeled by passing 11 μl of RBC suspension (Hematocrit = 6%) in phosphate buffer solution (PBS) of a viscosity of 1 and 2.6 cP (in the presence of 2% Dextran) through 5 μm pore diameter polycarbonate Nuclepore filters. We have developed a digitally controlled experimental system for measuring the RBC filterability at a constant driving pressure, in the range of 10–400 Pa, producing a wall shear stress range of 1–50 Pa. The RBC filterability was evaluated by measuring the cell suspension flow rate normalized by the PBS flow rate. The RBC filterability has been found to be a nonlinear function of the driving pressure, having a single minimum locus at 25 Pa. Lowering the driving pressure below 25 Pa revealed an unexpected increase of the RBC filterability. The maximal RBC filterability (near unity) was detected at the lowest driving pressure (10 Pa) and the corresponding estimated RBC linear velocity while traveling through the capillary pore was as high as 800 μm/s. Increasing the driving pressure above 25 Pa confirmed previous results, where RBC filterability is monotonically and asymptotically increasing. Increasing the PBS medium viscosity from 1 to 2.26 cP significantly attenuated the RBC filterability and led to the anomalous increase of RBC deformability at the 10 Pa pressure range. We propose that the anomalous increase in RBC deformability was caused by RBCs undergoing spontaneous mechanical fluctuations.
Keywords: RBC deformability, low Reynolds number, spontaneous mechanical fluctuations, Dextran solution viscosity, polycarbonate Nuclepore filters, wall shear stress
DOI: 10.3233/CH-2009-1242
Journal: Clinical Hemorheology and Microcirculation, vol. 43, no. 4, pp. 309-319, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl