Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers from the Regensburg Conference, Regensburg, Germany, 5–6 September 2008
Article type: Research Article
Authors: Jung, E.M.; | Schreyer, A.G. | Schacherer, D. | Menzel, C. | Farkas, S. | Loss, M. | Feuerbach, S. | Zorger, N. | Fellner, C.
Affiliations: Institute of Radiology, University Medical Center Regensburg, Regensburg, Germany | Department of Internal Medicine I and Radiology, Interdisciplinary Center of Clinical Ultrasound, University Medical Center Regensburg, Regensburg, Germany | Department of Surgery, University Medical Center Regensburg, Regensburg, Germany
Note: [] Corresponding author: Ernst Michael Jung, MD, Department of Radiology, University Medical Center Regensburg, Franz-Josef-Strauss Allee 11, 93053 Regensburg, Germany. E-mail: emjung@gmx.de.
Abstract: Aim: Evaluation and characterization of the vascularisation and perfusion of liver tumors by means of image fusion of dynamic contrast-enhanced ultrasound (CEUS), multidetector-CT (MD-CT) or magnetic resonance imaging (MRI) with the ultrasound navigation technique. Material: For interventional planning a real-time image fusion involving CEUS (LOGIQ E9, GE) was performed in 20 patients (12 men, 8 women, age 43–69 years, median 54) with histologically confirmed malignant liver tumors (9 × hepatocellular carcinoma (HCC), 5 × metastases, 2 × hemangiomas, 1 × cholangiocellular carcinoma (CCC), 1 × lymphoma, 1 × neuroendocrine tumor, 1 × focal nodular hypoplasia (FNH)). In 17 patients the real-time CEUS was fused with contrast-enhanced MD-CT and in three patients with contrast-enhanced MRI (Gd-DTPA and liver-specific contrast medium Resovist®). All of the ultrasound examinations were performed by an experienced examiner with a multi-frequency probe (2–5 MHz, LOGIQ E9, GE); dynamic image sequences up to 3 minutes in true agent detection mode of contrast harmonic imaging (CHI) were documented. An evaluation of the tumor was performed by the characterization of the dynamics of the contrast medium and microperfusion with CEUS, fused with MD-CT or MRI. Results: In 18/20 cases there was an accurate agreement with respect to the segmental localization of the tumor lesion. In 2/20 cases the localization was comparable with the image fusion of CEUS and reference imaging (a total of at least 65 lesions: 3 × 1 lesion, 5 × 2 lesions, 8 × 3 lesions, 2 × 5 lesions, 1 × 8 lesions, 1 × at least 10 lesions (multifocal)). With image fusion a certain characterization was attained in 17/20 cases. In 3/20 cases (lymphoma after liver transplantation, multifocal CCC, metastases of a neuroendocrine tumor) the diagnosis was at first doubtful and had to be confirmed histologically. In patients with HCC an evaluation of the tumor perfusion was feasible in all 9 cases (8/9 after local trans-arterial chemoembolization (TACE), 1/9 after radio frequency ablation (RFA)). A tendency toward the identification of more lesions with image fusion of CEUS and CT than with contrast-enhanced CT alone could be recognized (p=0.059). Conclusion: Applying a new real-time fusion technique of MD-CT or MRI with CEUS new possibilities for the evaluation, intervention and monitoring of the therapy of liver lesions were made possible, since the method also comprised the dynamic microperfusion.
Keywords: Real-time image fusion, contrast-enhanced ultrasound (CEUS), liver lesions, CT, MRI
DOI: 10.3233/CH-2009-1221
Journal: Clinical Hemorheology and Microcirculation, vol. 43, no. 1-2, pp. 57-69, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl