Article type: Research Article
Authors: Shi, Y.D.; | Artmann, G. | Agosti, R. | Longhini, E.
Affiliations: Department of Biophysics, Shanghai Medical University, Shanghai 200032, China | Department of Applied Cell Biophysics and Biomedical Engineering, Fachhochschule Aachen‐Jülich, 52428 Jülich, Germany | Hospital of Sesto San Giovanni, Via Matteotti 83, Milan, Italy
Note: [] Correspondence to: Y.D. Shi, Department of Biophysics, Shanghai Medical University, Shanghai 200032, China.
Abstract: A modified Casson equation was established, verified satisficatorily for real conditions and suggested for use in clinical hemorheology. It provides 5 Casson parameters, i.e., Casson yield stress, Casson viscosity, the first critical point of shear rate to cause rouleaux to be broken down into smaller units, the second critical point of shear rate to completely disaggregate into individual erythrocytes, the difference between the two critical points, and also gives two series of the 5 above‐mentioned Casson parameters, respectively, under original hematocrit and the standardized hematocrit of 45%. This equation not only reveals the apparent abnormalities of hypertensive patients and normalities of the healthy persons, but also reveals hidden abnormalities for patients with either low or high hematocrit. For 20 cases of hypertensive patients with low hematocrit, the 5 Casson parameters have lower values than control, but the modified equation reveals their hidden higher values than control when their hematocrit is standardized to 45%. For 7 cases of polycythemia complicated with hypertension, the 5 Casson parameters are higher at their original hematocrit, and the modified equation reveals the higher parameters than control also when the hematocrit is standardized to 45%. For 8 cases of polycythemia without complications, the 5 Casson parameters are higher at their original hematocrit than control, while the modified equation still reveals their normalities when standardizing their hematocrit to 45%.
Keywords: Casson equation, hypertension, hematocrit, hemorheology
Journal: Clinical Hemorheology and Microcirculation, vol. 19, no. 2, pp. 115-127, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl