Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Das, Rajarshi* | Pandey, A.D. | Soumya, | Mahesh, M.J.
Affiliations: Department of Earthquake Engineering, Indian Institute of Technology Roorkee, India
Correspondence: [*] Corresponding author. Rajarshi Das, Department of Earthquake Engineering, IIT Roorkee, 247667, India. Tel.: +917417304628; E-mail: rajarshidas91@gmail.com.
Abstract: Although the application of the Alternate Path method has well proven its efficiency towards increasing the structural robustness of bare frame structures against progressive collapse, it should be further developed for bridge structures, and especially cable stayed bridges, as they are the only type routinely designed for cable loss phenomenon. The main objective of this paper is to analyse a cable stayed bridge for multiple types of cable loss phenomenon to develop a profound knowledge regarding the overall structural response to local failure and the possibility of a failure progression throughout the structure. This paper demonstrates numerical modelling and analysis of a typical cable stayed bridge through a nonlinear static procedure using SAP 2000. The response of the structural model is discussed for multiple types of cable loss cases to identify a definite progressive collapse pattern. Furthermore, a categorical investigation of the impact ratios was also done for different structural properties through a dynamic analysis to recognize the lack of robustness in the structure. The results indicate different design considerations for different elements of the structure and also a variation in the possibility of failure progression through the cable stayed model depending upon the location of the failed cables. The prevailing collapse type is discussed with some suggestions for a more robust design.
Keywords: Progressive collapse, nonlinear static analysis, cable loss cases, structural failures, impact ratio, cable stayed bridges
DOI: 10.3233/BRS-160099
Journal: Bridge Structures, vol. 12, no. 1-2, pp. 41-51, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl