Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hsiu, Hsin; | Huang, Shih-Min | Hsu, Tse-Lin
Affiliations: Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, China | Department of Electrical Engineering, Yuan Ze University, Taoyuan, Taiwan, China | Biophysics Lab, Institute of Physics, Academia Sinica, Taipei, Taiwan, China
Note: [] Address for correspondence: Dr. Hsin Hsiu, 43, Section 4, Keelung Road, Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan, China. Tel.: +886 22730 3216; Fax: +886 22730 3733; E-mail: hhsiu@mail.ntust.edu.tw.
Abstract: Objective: We aimed to verify whether microcirculatory blood flow variability (MBFV) parameters calculated from beat-to-beat laser Doppler flowmetry (LDF) waveforms can be used instead of microcirculatory blood flow (MBF) as an index to discriminate different local microcirculatory regulation in terms of the opening condition of arteriolar openings (AO) at different sites. Methods: Angiotensin II (Ang-II) was administered to nine healthy male rats. LDF probes were placed on their renal cortex and plantar palm. The pulse width (PW) and coefficient of variance of the flux (ϕ) for all the pulses within a data sequence was calculated to evaluate the AO's opening condition. Results: Monitoring and prediction linear-regression analyses revealed significant positive ϕ-vs-μ (mean flux) and PW-vs-μ slopes at renal cortex for their changes relative to the baseline values. Conclusion: The present results suggest that these parameters calculated from the beat-to-beat LDF waveform could be useful for monitoring MBF by administering Ang-II. Moreover, possible time-domain causal relation between changes in μ and these parameters was revealed, which may allow the prediction of changes in MBF that occur 10–30 min thereafter. Deeper understanding of MBFV parameters could be useful in monitoring of progression of cardiovascular diseases and in predicting the efficacy of specific therapies.
Keywords: Microcirculatory blood flow, variability, angiotensin II
DOI: 10.3233/BIR-2010-0573
Journal: Biorheology, vol. 47, no. 3-4, pp. 239-253, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl