Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Karšaj, I. | Humphrey, J.D.;
Affiliations: Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia | Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
Note: [] Address for correspondence: Dr J.D. Humphrey, Department of Biomedical Engineering, 337 Zachry Engineering Center, 3120 TAMU, Texas A&M University, College Station, TX 77843-3120, USA. Tel.: +1 979 8455558; Fax: +1 979 8454450; E-mail: jhumphrey@tamu.edu.
Abstract: Quantifying mechanical properties of blood clots is fundamental to understanding many aspects of cardiovascular disease and its treatment. Nevertheless, there has been little attention to quantifying the evolving composition, structure and properties when a clot transforms from an initial fibrin-based mesh to a predominantly collagenous mass. Although more data are needed to formulate a complete mathematical model of the evolution of clot properties, we propose a general constrained mixture model based on diverse data available from in vitro tests on fibrinogenesis, the stiffness of fibrin gels, and fibrinolysis as well as histological and mechanical data from clots retrieved from patients at surgery or autopsy. In particular, albeit resulting from complex kinetics involving many clotting factors, we show that the rapid (minutes) in vitro production of fibrin from fibrinogen can be modeled well by an Avrami-type relation and similarly that the fast (tens of minutes) in vitro degradation of fibrin in response to different concentrations of plasmin can be captured via a single “master function” parameterized by appropriate half-times that can be inferred from laboratory or clinical data. Accounting simultaneously for the production and removal of fibrin as well as chemo-mechano-stimulated production of fibrillar collagens yields predictions of changing mass fractions and bulk mechanical properties that correspond well to experimentally available data. Constrained mixture models thus hold considerable promise for modeling the biomechanics of clot evolution and can guide the design and interpretation of needed experiments and stress analyses.
Keywords: Coagulation, blood clot, fibrin gel, collagen organization, mechanical stress
DOI: 10.3233/BIR-2009-0556
Journal: Biorheology, vol. 46, no. 6, pp. 509-527, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl