Article type: Research Article
Authors: Zhao, Rui | Antaki, James F. | Naik, Tikeswar | Bachman, Timothy N. | Kameneva, Marina V.; | Wu, Zhongjun J.;
Affiliations: Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA | Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA | McGowan Institute of Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA | Department of Surgery, University of Maryland School of Medicine, Baltimore, MD, USA
Note: [] Address for correspondence: Zhongjun J. Wu, PhD, Department of Surgery, University of Maryland School of Medicine, MSTF 434F, 10 South Pine Street, Baltimore, MD 21201, USA. Tel.: +1 410 706 7715; Fax: +1 410 706 0311; E-mail: zwu@smail.umaryland.edu.
Abstract: The understanding of erythrocyte deformation under conditions of high shear stress and short exposure time is central to the study of hemorheology and hemolysis within prosthetic blood contacting devices. A combined computational and experimental microscopic study was conducted to investigate the erythrocyte deformation and its relation to transient stress fields. A microfluidic channel system with small channels fabricated using polydimethylsiloxane on the order of 100 μm was designed to generate transient stress fields through which the erythrocytes were forced to flow. The shear stress fields were analyzed by three-dimensional computational fluid dynamics. Microscopic images of deforming erythrocytes were experimentally recorded to obtain the changes in cell morphology over a wide range of fluid dynamic stresses. The erythrocyte elongation index (EI) increased from 0 to 0.54 with increasing shear stress up to 123 Pa. In this shear stress range, erythrocytes behaved like fluid droplets, and deformed and flowed following the surrounding fluid. Cells exposed to shear stress beyond 123 Pa (up to 5170 Pa) did not exhibit additional elongation beyond EI=0.54. Two-stage deformation of erythrocytes in response to shear stress was observed: an initial linear elongation with increasing shear stress and a plateau beyond a critical shear stress.
Keywords: Red blood cell, blood damage, shear stress, elongation index
Journal: Biorheology, vol. 43, no. 6, pp. 747-765, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl