Article type: Research Article
Authors: Lee, D.a; * | Chiu, Y.L.a | Jen, C.J.b
Affiliations: [a] Institute of Aeronautics and Astronautics, National Cheng Kung University, Tainan, Taiwan, Republic of China | [b] Department of Physiology, College of Medicine, National Cheng Kung University, Tainan, Taiwan, Republic of China
Note: [*] Reprint request to: D. Lee, Institute of Aeronautics and Astronautics, National Cheng Kung University, Tainan, Taiwan, Republic of CHINA; Fax: -886-6-2740467; E-mail: fhlldenz@mail.iaa.ncku.edu.tw
Abstract: In the present study, the data of the initial adhesion of platelets onto the wall of a flow chamber with an obstacle in steady human blood flows were obtained. The flowfields and the distribution of stress-related factors were simulated numerically by a finite volume method and the fluid dynamic effect on the platelet adhesion is discussed. In addition to the wall shear effect, the normal stress effect was also taken into account. A parameter Vn/|Vt| was devised to assess the combined effect of both shear and normal forces in platelet adhesion. It was found that the peak adhesion occurred next to, but not on, the impingement point on the obstacle where the value of Vn/|Vt| was negative. In these regions, direct impact played a major role in platelet adhesion. On the other hand, near the separation point before the obstacle where Vn/|Vt| was insignificant, the mechanism was believed to be different from that in the direct impact region. Denser adhesion there might be caused by the accumulation and frequent collision of particles due to flow retardation and/ or detour of the flow path. Interestingly, relatively low adhesion was found inside the recirculation regions. These results show that the normal stress effect (impingement) should be considered in platelet adhesion in addition to the shear effect.
Keywords: Platelet adhesion, flow chamber, hemodynamic stresses
DOI: 10.3233/BIR-1997-34203
Journal: Biorheology, vol. 34, no. 2, pp. 111-126, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl