Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle: II. Hemodynamic impact of leukocytes adherent to the wall of post-capillary vessels
Article type: Research Article
Authors: Chapman, G.B.a | Cokelet, G.Rb; *
Affiliations: [a] Department of Biochemistry and Biophysics, University of Rochester, Rochester, New York, USA | [b] Department of Pharmacology and Physiology, University of Rochester, Rochester, New York, USA
Note: [*] Reprint requests to: Giles Cokelet, Department of Pharmacology and Physiology, University of Rochester, 601 Elmwood Avenue, Rochester, NY 14642, USA; Fax: (716) 244-9283; E-mail: cokelet@pharmacol.rochester.edu
Abstract: Computational fluid dynamics (CFD) and large scale model experiments were used to analyze the hemodynamic impact of leukocytes adherent to the wall of post-capillary venules. Using a large scale model and, with the aid of a finite element package, solving the Navier Stokes equations for low Reynolds number flow in a cylinder past an adherent sphere, we have developed a dimensionless correlation which permits the estimation of the pressure drop across an adherent leukocyte in an in vivo vessel. This relationship is: f·Re=exp[2.877+4.630(dD)4] where f is the Fanning friction factor, Re is the Reynolds number and d/D is the leukocyte to vessel diameter ratio. The friction factor is proportional to the pressure drop across the leukocyte, and does not significantly increase until d/D is greater than 0.5, and then increases rapidly with increasing d/D. Computations indicate that the length of the disturbed flow region generated by an adherent leukocyte increases with decreasing vessel size. The average wall stress in the disturbed flow region remains constant, and equal to the wall stress in the undisturbed region for d/D less than approximately 0.5. For d/D greater than 0.5, the average wall stress in the disturbed flow region increases rapidly with increasing d/D. There is an even larger increase, up to five times greater than the average disturbed stress, in the peak wall stress in the disturbed flow region. This indicates that significant wall stress gradients can be generated by an adherent leukocyte in post-capillary size vessels.
Keywords: Leukocyte, computational fluid dynamics, flow resistance, wall stress
DOI: 10.3233/BIR-1997-34103
Journal: Biorheology, vol. 34, no. 1, pp. 37-56, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl