Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Workshop: Breaking Symmetry in Haemodynamics, London, UK, 23–24 April 2001
Article type: Research Article
Authors: Caro, Colin; | Jeremy, Jamie | Watkins, Nick | Bulbulia, Richard | Angelini, Gianni | Smith, Frank | Wan, Song | Yim, Anthony | Sherwin, Spencer | Peiró, Joaquim | Papaharilaou, Yannis; | Falzon, Brian | Giordana, Sergio | Griffiths, Clydd
Affiliations: Department of Bioengineering, Imperial College, London, UK | Department of Aeronautics, Imperial College, London, UK | Bristol Heart Institute, University of Bristol, UK | Department of Surgery, Bristol Royal Infirmary, UK | Department of Surgery, Prince of Wales Hospital, Hong Kong
Note: [] Address for correspondence: Prof. C.G. Caro, Sir Leon Bagrit Centre, Department of Bioengineering, Imperial College, Exhibition Road, London SW7 2BX, UK. Tel.: +44 207 594 5180; Fax: +44 207 584 6897; E‐mail: c.caro@ic.ac.uk.
Abstract: The long‐term success of arterial bypass grafting with autologous saphenous veins is limited by neointimal hyperplasia (NIH), which seemingly develops preferentially at sites where hydrodynamic wall shear is low. Placement of a loose‐fitting, porous stent around end‐to‐end, or end‐to‐side, autologous saphenous vein grafts on the porcine common carotid artery has been found significantly to reduce NIH, but the mechanism is unclear. In a preliminary study, we implanted autologous saphenous vein grafts bilaterally on the common carotid arteries of pigs, placing a stent around one graft and leaving the contralateral graft unstented. At sacrifice 1 month post implantation, the grafts were pressure fixed in situ and resin casts were made. Unstented graft geometry was highly irregular, with non‐uniform dilatation, substantial axial lengthening, curvature, kinking, and possible long‐pitch helical distortion. In contrast, stented grafts showed no major dilatation, lengthening or curvature, but there was commonly fine corrugation, occasional slight kinking or narrowing of segments, and possible long‐pitch helical distortion. Axial growth of grafts against effectively tethered anastomoses could account for these changes. CFD studies are planned, using 3D MR reconstructions, on the effects of graft geometry on the flow. Abnormality of the flow could favour the development of vascular pathology, including NIH.
Keywords: Graft geometry, graft casts, graft elongation, graft buckling
Journal: Biorheology, vol. 39, no. 3-4, pp. 507-512, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl