Abstract: The rheology of blood is characterized by shear thinning, viscoelasticity, and thixotropy. Its rheological evaluation is usually accomplished using a torque balance technique during rotational viscometry. Because a stable torque balance does not develop instantly, studies of thixotropy and viscoelasticity of blood have usually been carried out only at low shear rate where their development is slow enough to be monitored accurately. The torque balance technique may be converted from static to dynamic by incorporating the rate of change of sensing system angular momentum. We have modified our Couette viscometer, adding a computer-controlled stepping motor and a second digital voltmeter. The latter is used to determine the angular position of the sensing system every 25 or 50 msec. The new approach allows rapid observation of the development and disappearance of shear stress, enabling us to examine the transient behavior of blood at moderate shear rate (1 to 100 inverse seconds). The transient flow behavior of blood at moderate shear rate is most easily compared directly with the behavior of Newtonian fluids. We present information about the response of our system using a torque balance observation rate of 20 per second. Blood’s viscoelasticity is observed to fall substantially as shear rate rises, while its thixotropic transient excess stress rises steadily with increasing shear rate.
Keywords: hemorheology, viscoelasticity, thixotropy, blood viscosity
DOI: 10.3233/BIR-1986-23105
Journal: Biorheology, vol. 23, no. 1, pp. 63-74, 1986
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl