Article type: Research Article
Authors: Dintenfass, Leopolda | Fu-lung, Liaob; *
Affiliations: [a] Kanematsu Memorial Institute, Sydney Hospital, Sydney 2000, Australia | [b] Academy of Traditional Chinese Medicine, Peking, People’s Republic of China
Note: [*] Liao Fu-lung is a Research Fellow (1980–1982) in L.D.’s Department of Haemorheology and Biorheology.
Note: [] Accepted by: Editor Y.C.B. Fung
Abstract: Flow instability has been observed in the plasma and in the blood of low haematocrit studied in the rotational rhombospheroid viscometer. As this observation is relevant, and fundamental, to all cone-in-cone and cone-and-plate viscometers, a detailed experimental series was carried out using a range of standard oils of different viscosities as well as blood of different haematocrits. The main attention was given to a shear rate of 180 sec−1, corresponding to 250 r.p.m. at angular gap of 5° (although a 10° gap has been also used). Linear regressions have been established for flow instability (given as percentage increase of the apparent viscosity). The linear regression for Newtonian oils was: y = −0.1258x + 1.962 ± 0.133, (r = −0.981); and for blood: y = −0.354x + 2.002 ± 0.116, (r = −0.983), in which y represents log of percentage increase of viscosity due to instability, and x is viscosity in cP or mPas.s. Flow instability occurs at higher shear rates in blood than in Newtonian oils; this is attributed to the pseudoplasticity (or shear-thinning or thixotropy) of blood. Both regressions merge at viscosity of under 1 cP, and spread apart as viscosities increase.
Keywords: Flow instability, Newtonian oils, Blood anti-instability property
DOI: 10.3233/BIR-1981-18202
Journal: Biorheology, vol. 18, no. 2, pp. 191-205, 1981
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl