Article type: Research Article
Authors: Skilbeck, Christopher | Westwood, Susan M. | Walker, Peter G. | David, Tim | Nash, Gerard B.;
Affiliations: Department of Physiology, The University of Birmingham, Birmingham, UK | Department of Mechanical Engineering, University of Leeds, Leeds, UK
Note: [] Address for correspondence: Dr. G.B. Nash, Division of Medical Sciences, The Medical School, The University of Birmingham, Birmingham B15 2TT, UK. Tel: +44 121 414 3670; Fax: +44 121 414 6919; E‐mail: g.nash@bham.ac.uk.
Abstract: We have recently described patterns of adhesion of different types of leukocytes downstream of a backward facing step. Here the predicted fluid dynamics in channels incorporating backward facing steps are described, and related to the measured velocities of flowing cells, patterns of attachment and characteristics of rolling adhesion for neutrophils perfused over P‐selectin. Deeper (upstream depth 300 μm, downstream depth 600 μm, maximum wall shear stress ∼0.1 Pa) and shallower (upstream depth 260 μm, downstream depth 450 μm, maximum wall shear stress ∼0.3 Pa) channels were compared. Computational fluid dynamics (CFD) predicted the presence of vortices downstream of the steps, distances to reattachment of flow, local wall shear stresses and components of velocity parallel and perpendicular to the wall. Measurements of velocities of perfused neutrophils agreed well with predictions, and suggested that adhesion to P‐selectin should be possible in the regions of recirculating flow, but not downstream in re‐established flow in the high shear channel. When channels were coated with a P‐selectin–Fc chimaera, neutrophils were captured from flow and immobilised. Capture showed local maxima around the reattachment points, but was absent elsewhere in the high shear chamber. In the low shear chamber there was depression of adhesion just beyond the reattachment point because of expansion of flow and depeletion of neutrophils near the wall. Inside the recirculation zones, adhesion decreased approaching the step because of an increasing, vertically upward velocity component. When channels were coated with P‐selectin, neutrophils rolled in all regions, but lifted off the surface as they rolled backwards into low shear regions near the step. Rolling velocity in the recirculation zone was independent of shear stress, possibly because of the effects of vertical lift. We conclude that while local wall shear stress influences adhesive behavior, delivery of cells to the wall and their behavior after capture also depend on components of flow perpendicular to the wall.
Journal: Biorheology, vol. 38, no. 2-3, pp. 213-227, 2001
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl