Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Sun, Yuchun; | Yuan, Fusong; | Li, Hong | Zhao, Yijiao | Lv, Peijun | Wang, Yong;
Affiliations: Peking University School of Stomatology Center of Digital Dentistry , Research Center of Engineering and Technology for Digital Dentistry, Ministry of Health and National Engineering Laboratory for Digital and material technology of stomatology, 22 Zhongguancun Nandajie, Haidian District, Beijing, P.R. China
Note: [] These two authors contributed equally
Note: [] These two authors contributed equally
Note: [] Corresponding author. E-mail: kqcadc@bjmu.edu.cn. Phone: +86-10-62188981 Fax: +86-10-62142111
Abstract: This study was to design a method to quantitatively evaluate three-dimensional (3D) reconstruction accuracy of spatial relationship of dental models based on a 7-axis contact 3D measuring system, and to evaluate the accuracy of a common regional registration method for edentulous jaw relation reconstruction. 3D surface data of edentulous dental casts with 10 positioning cylinders and wax occlusion rims of five patients were obtained using a dental scanner. The jaw relation was reconstructed using the common regional registration in the Geomagic software. Measurements were obtained for line length, vertical distance and horizontal distance between centric points from two sources with upper jaw model base plane as a reference plane. The statistical description of measurement data was done. $\bar{x}\pm s$ of line length, vertical distance and horizontal distance between the center points of each data set were 0.107±0.354, 0.076±0.576 and 0.108±0.530 mm, respectively. Data was analyzed using the paired samples t-test and one-way analysis of variance. Paired t-test results of each patient and one-way analysis of variance for the five patients showed no significant differences (P>0.05). Using the Faro Edge system and standardized positioning cylinders, quantitative evaluation of the 3D reconstruction accuracy of edentulous jaw relation was workable. And results of common regional registration method met clinical requirements.
Keywords: Edentulous jaw, jaw relation, three-dimensional scanning, three-dimensional reconstruction
DOI: 10.3233/BME-130930
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 1275-1287, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl