Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Gao, Hongzhi | Lu, Qipeng; | Ding, Haiquan
Affiliations: State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
Note: [] Address for correspondence: Qipeng Lu, State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, P.R. China. E-mail: luqipeng@126.com.
Abstract: Subtracted blood volume spectrometry (SBVS) can eliminate the background information in near infrared spectroscopy (NIRS) noninvasive biochemical sensing. However, the spectrum obtained by this method is accompanied by serious noises which are to the disadvantage of the calibration models. Empirical mode decomposition (EMD) was applied to restrict the noises in order to improve the performance of subtracted blood volume spectrometry. Certain criteria were used to evaluate the performance of the method, such as the average correlation coefficient, and the average and standard deviation of the Euclidean distance. EMD was applied to three subtracted spectra with different ΔL, and the criteria were calculated accordingly. All of the criteria were improvement. Especially for the subtracted spectra with ΔL=0.5mm, the correlation coefficient increased from 0.9970 to 0.9999, the average Euclidean distance decreased from 0.0265 to 0.0118, and the standard deviation of the Euclidean distance decreased from 0.0148 to 0.0033 after EMD filtering. The PLS models of the processed spectra were promoted as well. These preliminary results suggest that EMD is a promising means of improving the performance of subtracted blood volume spectrometry.
Keywords: Near-infrared spectroscopy, noninvasive biochemical sensing, subtracted blood volume spectrometry, empirical mode decomposition
DOI: 10.3233/BME-130789
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 101-107, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl