Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Issue on Artificial Organs and Regenerative Medicine dedicated to the late Prof. Yukihiko Nosé
Article type: Research Article
Authors: Mitamura, Yoshinori; | Yano, Tetsuya | Nakamura, Wataru | Okamoto, Eiji
Affiliations: Graduate School of Information Science and Technology, Hokkaido University, Sapporo, Japan | Department of Machine Intelligence and Systems Engineering, Faculty of Systems Science and Technology, Akita Prefectural University, Yuri-Honjo, Japan | Department of Human Science and Informatics, School of Biological Science and Engineering, Tokai University, Sapporo, Japan
Note: [] Address for correspondence: Yoshinori Mitamura, 5-5-1-2 Sumikawa, Minami-ku, Sapporo 005-0005, Japan. Tel.: +81 11 812 3690; Fax: +81 11 812 3690; E-mail: ymitamura@par.odn.ne.jp
Abstract: A magnetic fluid (MF) seal has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids (several days). We have developed an MF seal that has a shield mechanism. The seal was perfect for 275 days in water. To investigate the effect of a shield, behaviors of MFs in a seal in water were studied both experimentally and computationally. (a) Two kinds of MF seals, one with a shield and one without a shield, were installed in a centrifugal pump. Behaviors of MFs in the seals in water were observed with a video camera and high-speed microscope. In the seal without a shield, the surface of the water in the seal waved and the turbulent flow affected behaviors of the MFs. In contrast, MFs rotated stably in the seal with a shield in water even at high rotational speeds. (b) Computational fluid dynamics analysis revealed that a stationary secondary flow pattern in the seal and small velocity difference between magnetic fluid and water at the interface. These MF behaviors prolonged the life of an MF seal in water.
Keywords: Magnetic fluid, magnetic fluid seal, rotary blood pump, computational fluid dynamics
DOI: 10.3233/BME-120733
Journal: Bio-Medical Materials and Engineering, vol. 23, no. 1-2, pp. 63-74, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl