Article type: Research Article
Authors: Zuccari, A.G. | Oshida, Y.; | Okamura, M. | Paez, C.Y. | Moore, B.K.
Affiliations: Prosthodontics, Department of Restorative Dentistry, Indiana University, School of Dentistry, Indianapolis, Indiana, USA | Dental Materials, Department of Restorative Dentistry, Indiana University, School of Dentistry, Indianapolis, Indiana, USA | Private Practice, Hakata, Fukuoka, Japan
Note: [] Correspondence and reprint requests should be addressed to Dr. Y. Oshida, Dental Materials Research Laboratory, Department of Restorative Dentistry, Indiana University School of Dentistry, 1121 West Michigan Street, Indianapolis, IN 46202-5186, USA.
Abstract: Articulating paper/film is a sheet strip that is coated with ink- or dye-containing wax and is used for marking occlusal contacts and monitoring the results. New types of occlusal film systems have been developed recently, which are capable of being computer-interfaced to identify the occlusal contact points and digitize the occlusal force. The mechanical ductility and thickness of these occlusal sheets constitute some of their important properties. The objective of this study was to evaluate seven different occlusal sheets and compare their bulge ductility and thickness. A custom-designed photo-sensing bulge tester was used. Three paper-based sheets (BAP, BET and SFA), two plastic-based sheets (ACF and AOS), and advanced systems (TSS and FDP) were tested. The specimen size was 20 mm square. Fifteen samples were tested for each material. The sheet film thickness with coated layers was as follows: BAP, 62 μm; BET, 46μm; SFA, 133 μm; ACF, 23 μm; AOS, 14 μm; TSS, 134 μm; and FDP, 82μm. Ductility (standard deviation) was as follows: BAP, 2.10 (0.006)%; BET, 2.14 (0.008)%; SFA, 5.19 (0.57)%; ACF, 8.68 (0.05)%; AOS, 5.61 (0.05)%; TSS, 16.26 (0.41)%; and FDP, 6.37 (0.09)%. One-way ANOVA analysis indicated that (1) there in no statistical difference between BAP and BET (p > 0.001), (2) there is a statistical difference (p < 0.001) among all the rest of the tested occlusal sheets, and (3) bulge ductility appears to be linearly related to film thickness, its correlation depending upon types of base materials.
Keywords: Occlusal films/papers, elongation, bulge ductility, occlusal contacts, film thickness
DOI: 10.3233/BME-1997-7405
Journal: Bio-Medical Materials and Engineering, vol. 7, no. 4, pp. 265-270, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl