Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kohn, Mark D. | Sun, Yu-long | Zhao, Chunfeng | Thoreson, Andrew R. | Jay, Gregory D. | An, Kai-Nan | Amadio, Peter C.;
Affiliations: Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN, USA | Department of Emergency Medicine, Rhode Island Hospital & Brown University, Providence, RI, USA
Note: [] Address for correspondence: Peter C. Amadio, MD, Mayo Clinic, Orthopedic Biomechanics Laboratory, 200 1st Street SW, Rochester, MN 55905, USA. Tel.: +1 507 538 1717; Fax: +1 507 284 5392; E-mail: pamadio@mayo.edu.
Abstract: The lubricating ability of human synoviocyte lubricin and bovine lubricin purified from synovial fluid was investigated and compared using a canine in vitro tendon model. Our null hypothesis was that these two forms of lubricin would have equal lubricating ability. Forty two canine hind-limbs were used. The peroneus longus (PL) tendons were harvested, along with the proximal phalanx and flexor digitorum profundus of the second or fifth digit with its proximal fibro-osseous pulley. Forty PL tendons were randomly assigned to one of four treatment groups. After gliding resistance testing, two intact PL tendons and two tendons in each group were randomly selected for surface observation with scanning electron microscopy (SEM). The variance of the PL saline group mean gliding resistance was significantly different from other groups. There was a significant treatment-cycle interaction effect on the mean gliding resistance. On SEM, the surface of the saline treated PL tendons appeared rough, whereas the other tendon surfaces appeared smooth. Human synoviocyte lubricin functioned as well as bovine synovial fluid lubricin to reduce friction of canine PL tendons in vitro. This data suggest that treatment using the two forms of lubricin are mechanically similar.
Keywords: Human bovine lubricin, gliding resistance, flexor tendon
DOI: 10.3233/BME-2012-0676
Journal: Bio-Medical Materials and Engineering, vol. 21, no. 5-6, pp. 281-289, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl