Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers from the 5th Scientific Meeting on Cartilage Engineering, February 2010, Nancy, France
Article type: Research Article
Authors: Zille, Hervé | Paquet, Joseph | Henrionnet, Christel | Scala-Bertola, Julien | Leonard, Michèle | Six, Jean Luc | Deschamp, Frantz | Netter, Patrick | Vergès, José | Gillet, Pierre; | Grossin, Laurent
Affiliations: Physiopathologie, Pharmacologie et Ingénierie Articulaires, UMR 7561 CNRS UHP, Nancy, France | Laboratoire de Chimie-Physique Macromoléculaire, UMR CNRS-INPL 7568 ENSIC, Nancy, France | SEPAREX SA, Champigneulles, France | BIOIBERICA SA, Barcelona, Spain
Note: [] Address for correspondence: Pierre Gillet, Physiopathologie, Pharmacologie et Ingénierie Articulaires, UMR 7561 CNRS UHP, Nancy, France. E-mail: Pierre.Gillet@medecine.uhp-nancy.fr.
Abstract: The aim of this study is to evaluate the toxicity of nanoparticles of poly(D,L-lactic acid) (PLA) or poly(D,L-lactic-co-glycolic acid) (PLGA) covered by chemically esterified amphiphilic hyaluronate (HA) which will be used for intra-articular injection as a drug carrier for the treatment of arthritis (RA) and/or osteoarthritis (OA). PLA and PLGA are FDA approved polymers that are already used for the preparation of nano or microparticles. HA is a natural polysaccharide already present in the articulations known to interact with the CD44 receptors of the cells (especially chondrocytes). Therefore, we can envisage that the HA covering can improve the interactions between the cells and the nanoparticles, leading to better targeting or biodistribution. The knee of healthy male rats was injected one to two times weekly, with various concentrations of nanoparticles encapsulating Dextran-FITC. The synovial membranes and the patellae were collected aseptically and histologically analyzed to assess the effects and localization of the nanocapsules in the knee joint. We did not observe significant modifications in the synovial membranes (weak hyperplasia) or patellae integrity after local administration of nanodevices into the rats. While we found some nanoparticles in the synovial membrane, none were detected in the patellae. Moreover, the histological observations for patellae were confirmed by radiosulfate intake, which depicted no decrease in proteoglycans biosynthesis in nanoparticles treated animals. Concerning the safety towards synovial membranes, we also had a look at the inflammatory response after injections of nanoparticles covered by amphiphilic HA or polyvinyl alcohol (PVA) by monitoring the mRNA expression levels of some specific early cytokines (IL-1β and TNF-α). Once again, no differences were observed between the control rats and the rats treated with nanoparticles. Considering these preliminary results obtained in healthy rats, we can establish that neither the amphiphilic HA-covered PLGA nanoparticles nor their degradation products induce major modifications of articular tissues functions, while injected into the knee of healthy rats. These results should be confirmed in OA or RA rat models, in order to confirm that nanoparticles do not worsen already altered (degenerative or inflamed) articular tissues. Once confirmed, such tuneable nanoparticles could be proposed as a safe drug delivery system for the treatment of articular disease, allowing a wide range of encapsulating molecules.
Keywords: Intra-articular injection, hyaluronate, nanoparticles
DOI: 10.3233/BME-2010-0637
Journal: Bio-Medical Materials and Engineering, vol. 20, no. 3-4, pp. 235-242, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl