Article type: Research Article
Authors: Ishida, Hitoshi; | Satou, Toshio | Tsuji, Kiichi | Kawashima, Norimichi | Takemura, Hideo | Kosaki, Yasuhiro | Shiratori, Seimei | Agishi, Tetuzou
Affiliations: Toin University of Yokohama, Yokohama, Japan | Tokatu Clinic Hospital, Tokyo, Japan | Keio University, Tokyo, Japan | Itabashi Chuo General Hospital, Tokyo, Japan
Note: [] Address for correspondence: H. Ishida, 1614, Kurogane-cyou, Aoba-ku, Yokohama, 225-8502 Japan. Tel.: +8190 7737 0072; E-mail: ishida@gaku-oki.ac.jp.
Abstract: Recently, expired gases are analyzed non-invasively for monitoring the substances in the blood. Breath ammonia has been shown to correlate with BUN (blood urea nitrogen) and Cr (creatinine), both of which are indicators of solute removal in hemodialysis. In this study, breath ammonia concentration was continuously measured using a crystal oscillator QCM (quartz crystal microbalance) during the expiration of patients undergoing dialysis treatment. The results show that NH3 (ammonia) decreased gradually as the treatment proceeded. A strong correlation was observed between changes in the frequency of the QCM gas sensor and both the pre-dialysis BUN level (r=0.71, p<0.05) and the post-dialysis BUN level (r=0.90, p<0.05). NH3 was found to fall precipitously during dialysis. The differences were statistically significant. In addition, we found a statistically significant correlation between BUN and NH3 in expired gas. These results suggest that continuous measurement of NH3 is useful to assess the status of solute removal during hemodialysis.
Keywords: Expired gas, non-invasive analysis, hemodialysis, QCM, BUN, Cr
DOI: 10.3233/BME-2008-0513
Journal: Bio-Medical Materials and Engineering, vol. 18, no. 2, pp. 99-106, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl