Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Geng, Jianhua | Chen, Yingmao; | Chen, Shengzu | Si, Hongwei | Tian, Jiahe
Affiliations: Department of Nuclear Medicine, Cancer Hospital, Chinese Academy of Medical Sciences, Beijing 100021, China | Department of Nuclear Medicine, General Hospital of PLA, Beijing 100853, China
Note: [] Address for correspondence: Yingmao Chen, Department of Nuclear Medicine, General Hospital of PLA, Fuxing Street 28, Beijing 100853, China. E-mail: gjean@sohu.com; chen.ym@263.net.
Abstract: The standard uptake value (SUV) is an important semi-quantitative parameter in positron emission tomography (PET). But SUV is not available in dual-head coincidence imaging system (DHC) which is widely used in clinical practice. This study was designed to develop a method for measuring SUV in DHC system, and then compared SUV in DHC and SUV in PET. Method: Firstly, the calibration factor (CF) for converting the voxel count rate to radioactivity concentration was determined by a phantom study in DHC. Then the method for calculating SUV in DHC was formulated. Finally, SUV in DHC and SUV in PET were compared through another phantom study. The phantoms used in the comparing study were cylindrical and consisted of several hot lesions. Results: The CF varied with the detected single count rate in a biquadratic polynomial; the lesion's radioactivity concentration was got based on the CF and the voxel count rate. From the lesion's radioactivity concentration, the lesion's SUV in DHC was obtained. The comparison study showed that SUV in PET was higher than SUV in DHC. The SUV in both DHC and PET increased with increasing sizes of lesions and were related with the reconstruction algorithm. Conclusions: SUV in DHC images could be obtained in our method; the value in DHC images was lower than that in PET image; and many factors, such as system performance, lesion's size, and reconstruction algorithm could influence the SUV accuracy in both DHC and PET.
Keywords: Dual-head coincidence imaging system (DHC), standard uptake value (SUV), positron emission tomography (PET)
Journal: Bio-Medical Materials and Engineering, vol. 17, no. 4, pp. 219-227, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl