Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Oshida, Y.; | Hashem, A. | Nishihara, T. | Yapchulay, M. V.
Affiliations: Dental Materials Laboratory, Department of Restorative Dentistry, Indiana University School of Dentistry, 1121 West Michigan Street, Indianapolis, IN 46202-5186, USA | Department of Mechanical Engineering. Kokushikan University, Faculty of Engineering, Tokyo, Japan | Prosthdontics, Department of Restorative Dentistry, Indiana University School of Dentistry, 1121 West Michigan Street, Indianapolis, IN, 46202-5186, USA
Note: [] All correspondence regarding this paper should be addressed to Yoshiki Oshida, PhD, Dental Materials Laboratory, Department of Restorative Dentistry, Indiana University School of Dentistry, 1121 West Michigan Street, Indianapolis, IN 46202-5186, USA, Tel: .(317) 274-3725, Fax: (317) 274-2419.
Abstract: In addition to biological and mechanical compatibilities for promising implant materials, a morphological compatibility is proposed by the authors. It has been reported by many investigators that implant surface with appropriate roughness and pore size exhibit better bone ingrowth activities. However, these parameters cannot characterize the complexity of surface textures. In the present study, dentulous and edentulous mandibular alveolar bones were utilized. Four segments from each mandible were subjected to the Fractal Dimension (DF) analysis. It was found that the dentulous mandible showed the DF of 1.81 ± 0.03 while the edentulous mandible exhibitedDF of 1.55 ± 0.07, indicating that the former has more complex surface texture. It was also found that there could be a linear relationship between the surface roughness and the fractal dimension.
Keywords: morphological compatibility, surface texturing, implants, fractal dimension, mandibular bones
DOI: 10.3233/BME-1994-4506
Journal: Bio-Medical Materials and Engineering, vol. 4, no. 5, pp. 397-407, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl