Article type: Research Article
Authors: Tai, Ching‐Lung; | Lee, Mel S. | Chen, Weng‐Pin | Hsieh, Pang‐Hsin | Lee, Po‐Chen | Shih, Chun‐Hsiung; ;
Affiliations: Department of Biomedical Engineering, Chung‐Yuan Christian University, Chungli, Taiwan | Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Kweishan, Taiwan | Department of Orthopedic Surgery, Chung Shan Hospital, Taipei, Taiwan
Note: [] Corresponding author: Chun‐Hsiung Shih, MD, Department of Orthopedic Surgery, Chang Gung Memorial Hospital, 5, Fu‐Hsin Street, Kweishan, Taoyuan 333, Taiwan. Tel.: +886 3 3281200, ext. 2163; Fax: +886 3 3278113; E‐mail: ortholab@adm.cgmh.org.tw.
Abstract: Local bone loss after implantation of traditional stem‐type prostheses remains an unsolved problem during the long‐term application of total hip replacement. The stress shielding effect and osteolysis were thought to be the two main factors that result in local bone loss after prosthesis implantation. A newly designed stemless cervico‐trochanteric (C‐T) prosthesis was thus developed to reduce stress shielding and osteolysis caused by the implantation of conventional stem‐type prosthesis. Eight synthetic femora were implanted with C‐T and porous coated anatomic (PCA) prostheses. Under 2,000‐Newton load, the surface strains of proximal femora were compared between the intact, PCA press‐fit femora and the C‐T implanted femora with three different fixation modes: two‐screw fixation, three‐screw fixation, and three‐screw combined with cement fixation. The results revealed that stress shielding in the C‐T implanted femora was significantly eliminated compared to that of the PCA implanted femora (p<0.01). No statistical difference in strain magnitude was found for the C‐T implanted femora among the three different fixation modes (p>0.1). The C‐T implanted femur has more physiological strain distribution. Moreover, from the C‐T prosthetic characteristic design, the localized osteolysis would be also reduced due to the overall coverage of neck‐trochanteric area. The newly designed C‐T prosthesis may be a useful alternative to the traditional stem‐type prosthesis in the future.
Keywords: Hip arthroplasty, stemless prosthesis, strain measurement, stress shielding, osteolysis
Journal: Bio-Medical Materials and Engineering, vol. 15, no. 3, pp. 239-249, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl