Article type: Research Article
Authors: Fukui, Tomohiro; | Matsumoto, Takeo; | Tanaka, Toshihiro | Ohashi, Toshiro | Kumagai, Kiichiro | Akimoto, Hiroji | Tabayashi, Koichi | Sato, Masaaki
Affiliations: Graduate School of Mechanical Engineering, Tohoku University, Aramaki-Aoba 01, Aoba-ku, Sendai, Miyagi 980-8579, Japan | Department of Engineering Physics, Electronics and Mechanics, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan | Department of Thoracic and Cardiovascular Surgery, Graduate School of Medicine, Tohoku University, Seiryo-machi 1-1, Aoba-ku, Sendai, Miyagi 980-8575, Japan
Note: [] Corresponding author: Tomohiro Fukui, Aramaki-Aoba 01, Aoba-ku, Sendai, Miyagi 980-8579, Japan. Tel.: +81 22 217 6958; Fax: +81 22 217 6959; E-mail fukui@pfsl.mech.tohoku.ac.jp.
Abstract: To investigate the mechanism of aneurysm rupture, it is necessary to examine the mechanical properties of aneurysm tissues in vivo. A new approach to evaluate in vivo mechanical properties of aortic aneurysmal tissues has been proposed in this study. The shape of the aneurysm was modeled as a sphere, and equi-biaxial stress in the in vivo state was estimated from the diameter and the wall thickness of each aneurysm and mean blood pressure of each patient. The mechanical properties of the aneurysm at the in vivo stress were estimated from its in vitro biaxial tensile properties. There were no significant correlations among maximum diameter D, wall thickness t, and mean infinitesimal strain in the in vivo state εm. This indicates the wall deformation during aneurysm development was not elastic but plastic. The mean incremental elastic modulus Hm, an index of tissue stiffness, had a significant positive correlation with elastic modulus anisotropy index KH. This indicates the aneurysmal wall got more anisotropic in vivo as it becomes stiffer.
Keywords: Aortic aneurysm, anisotropy, equibiaxial property
Journal: Bio-Medical Materials and Engineering, vol. 15, no. 4, pp. 295-305, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl