Authors: Lewandrowski, Kai‐Uwe | Bondre, Shrikar P. | Wise, Donald L. | Trantolo, Debra J.;
Affiliations: Orthopaedic Research Laboratories, Massachusetts General Hospital , Boston, MA 02114, USA | Cambridge Scientific, Inc. 180 Fawcett Street, Cambridge, MA 02138, USA
Note: [] Corresponding author: Debra J. Trantolo, Ph.D., Cambridge Scientific, Inc. 180 Fawcett Street St., Cambridge, MA 02138, USA. Tel.: 617 576 2663; Fax: 617 547 2663; E‐mail: dtrantolo@aol.com.
Abstract: The tissue response of subchondral bone to a biodegradable fixation device manufactured in the shape of a screw and made of polylactide with a hydroxyapatite buffer were implanted through the articular surface of the intercondylar portion of the distal rabbit femur. One screw was implanted per animal. The screws had a core diameter of 3.2 mm and an outer diameter of 4.5 mm. At insertion, the implants were cut flush with the articular surface. After follow‐up times of 8 and 16 weeks, the specimens were examined radiographically and histomorphometrically. The intact contralateral femur served as a control for comparison. Only minimal signs of degradation of the polymer could be seen in the histologic specimens. These implant degradation sites were commonly areas of new bone formation adjacent to the screw implant. A brim of repair tissue was formed at the entrance and exit of the implant channel. The width of the repair tissue from the tissue–implant boundary towards the center of the entrance hole varied greatly between the specimens, from 80 to 750 μm. In most specimens this bridging tissue consisted of newly formed bone and undifferentiated mesenchymal tissue. Degenerative chondrocyte clustering occurred in the pre‐existing cartilage within a 400 μm wide zone from the tissue–implant interface into the recipient tissues. Some new‐bone formation was seen to envelop the implant in all specimens, but the fractional osteoid formation surface of the trabeculae was only significantly higher in the screw‐implanted 16‐week specimens, when compared to the non‐operated contralateral controls. Although the bony osteotomy was invariably healed in all specimens with good implant integration, the quality and quantity of the reparative tissue of the articular cartilage near the screw hole was variable. This study showed that large polylactide implants, which are buffered with hydroxyapatite show benign tissue responses and good implant osteointegration when implanted in bone. They may be suitable for fixation of small bone fractures. However, insertion through intra‐articular surfaces may require further improvement of the implant material to avoid the degenerative repair processes seen in this study.
Keywords: Bioresorbable screw, hydroxyapatite, osteotomy healing, implant osteointegration
Journal: Bio-Medical Materials and Engineering, vol. 12, no. 3, pp. 259-270, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl