Authors: Athani, Abdulgaphura | Ghazali, Nik Nazri Nika; | Badruddin, Irfan Anjumb; c; | Kamangar, Sarfarazc | Anqi, Ali E.c | Algahtani, Alib; c
Affiliations: [a] Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia | [b] Research Center for Advanced Materials Science (RCAMS), King Khalid University, Abha, Asir, Kingdom Saudi Arabia | [c] Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Asir, Kingdom Saudi Arabia
Correspondence: [*] Corresponding authors: Nik Nazri Nik Ghazali. E-mail: nik_nazri@um.edu.my. Irfan Anjum Badruddin. E-mail: magami.irfan@gmail.com
Abstract: BACKGROUND:The blood flow in the human artery has been a subject of sincere interest due to its prime importance linked with human health. The hemodynamic study has revealed an essential aspect of blood flow that eventually proved to be paramount to make a correct decision to treat patients suffering from cardiac disease. OBJECTIVE:The current study aims to elucidate the two-way fluid-structure interaction (FSI) analysis of the blood flow and the effect of stenosis on hemodynamic parameters. METHODS:A patient-specific 3D model of the left coronary artery was constructed based on computed tomography (CT) images. The blood is assumed to be incompressible, homogenous, and behaves as Non-Newtonian, while the artery is considered as a nonlinear elastic, anisotropic, and incompressible material. Pulsatile flow conditions were applied at the boundary. Two-way coupled FSI modeling approach was used between fluid and solid domain. The hemodynamic parameters such as the pressure, velocity streamline, and wall shear stress were analyzed in the fluid domain and the solid domain deformation. RESULTS:The simulated results reveal that pressure drop exists in the vicinity of stenosis and a recirculation region after the stenosis. It was noted that stenosis leads to high wall stress. The results also demonstrate an overestimation of wall shear stress and velocity in the rigid wall CFD model compared to the FSI model.
Keywords: Left coronary artery, image processing, CFD, FSI, blood flow modeling
DOI: 10.3233/BME-201171
Journal: Bio-Medical Materials and Engineering, vol. 33, no. 1, pp. 13-30, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl