Article type: Research Article
Authors: Hayashi-Sakai, Sachikoa; | Kobayashi, Taichia | Sakamoto, Makotob | Hayashi, Takafumia | Morise, Yusukec | Nikkuni, Yutakaa | Takamura, Masakia | Sakai, Jund | Shimomura-Kuroki, Junkoe | Ike, Makikoa | Nishiyama, Hideyoshia
Affiliations: [a] Division of Oral and Maxillofacial Radiology, Faculty of Dentistry and Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan | [b] Graduate School of Health Sciences, Niigata University, Niigata, Japan | [c] Department of Mechanical Engineering, Faculty of Engineering, Niigata University, Niigata, Japan | [d] Department of System and Automotive Engineering, Niigata College of Technology, Niigata, Japan | [e] Department of Pediatric Dentistry, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan
Correspondence: [*] Corresponding author: Sachiko Hayashi-Sakai, Division of Oral and Maxillofacial Radiology, Faculty of Dentistry and Graduate School of Medical and Dental Sciences, 2-5274 Gakkocho-Dori, Chuo-ku, Niigata 951-8514, Japan. Tel.: +81 25 227 2916; Fax: +81 25 227 0810; E-mail: sachipro@dent.niigata-u.ac.jp
Abstract: BACKGROUND:Lip closing functions have never been evaluated from the viewpoint of elastic properties. OBJECTIVES:The purpose of the present study was to investigate the behavior of the lower orbicularis oris muscle during a button-pull exercise to measure lip closing force and quantitatively evaluate its elastic properties using sonographic elastography. METHODS:Appropriate compression loads for elastography were randomly measured on one of three types of acoustic couplers on three examiners. Compression tests were performed on three types of acoustic couplers within the appropriate compression load. Using the acoustic coupler with the lowest elastic modulus, the strain ratio of the lower orbicularis oris muscle during lip closing was measured, and elastography was performed on six males under tension loads of 0–8 N. RESULTS:The intraclass correlation coefficient (1, 3) for the tension load of 0 N was 0.81. Elastography showed that the strain ratio values increased significantly (p < 0.05) as the tension load increased. CONCLUSIONS:Combining the data obtained from lip closing test devices and sonographic elastography enabled the muscle performance to be evaluated objectively and accurately.
Keywords: Lip closing function, lower orbicularis oris muscle, ultrasound, sonographic elastography, strain ratio, elasticity
DOI: 10.3233/BME-201101
Journal: Bio-Medical Materials and Engineering, vol. 31, no. 6, pp. 361-371, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl