Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lee, Jin-Aha; † | Koh, Yong-Gonb; † | Kang, Kyoung-Taka;
Affiliations: [a] Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea | [b] Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, Republic of Korea
Correspondence: [*] Corresponding author: Kyoung-Tak Kang, Ph.D., Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea. Tel.: +82 2 2123 4827; Fax: +82 2 362 2736; E-mail: tagi1024@gmail.com
Note: [†] Jin-Ah Lee and Yong-Gon Koh contributed equally to this work and should be considered co-first authors.
Abstract: BACKGROUND:The post-cam mechanism in the posterior-stabilized (PS) implant plays an important role, such as durability and kinematic performances, in total knee arthroplasty (TKA). OBJECTIVE:The purpose of this study was to evaluate the difference in the kinematics and contact stress of five post-cam designs, which are flat-and-flat, curve-and-curve (concave), curve-and-curve (concave and convex), helical, and asymmetrical post-cam designs, using three-dimensional finite element models. METHODS:We designed the post-cam model with five different geometries. The kinematics, contact stress, and contact area were evaluated in the five post-cam designs under gait cycle loading conditions using the finite element method. RESULTS:There were no differences in the contact stress and area on the tibial insert in all designs. The largest internal rotation was shown in the swing phase for the helical design, and the largest tibial posterior translation was observed for the curve-and-curve (concave) design. The curve-and-curve (concave) design showed the lowest contact stress and the largest posterior tibial translation during the gait cycle. CONCLUSIONS:Considering the kinematics and contact stress, we found that the curve-and-curve (concave) design was more stable than other designs. From the results, we found the important factors of TKA implant considering stability and kinematics.
Keywords: Total knee arthroplasty, implant, kinematics, design, gait
DOI: 10.3233/BME-201097
Journal: Bio-Medical Materials and Engineering, vol. 32, no. 6, pp. 323-332, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl