Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Brun, J. L. | Bordenave, L. | Lefebvre, F. | Bareille, R. | Barbié, C. | Rouais, F. | Baquey, Ch.
Affiliations: INSERM U.306, Université de Bordeaux II, 146, rue Léo Saignat, 33076 Bordeaux Dédex, France
Abstract: Our study compared mechanical and biological properties of four materials classically used in surgery: polyethylene terephtalate (Mersilene®), polypropylene (Marlex®), polytetrafluoroethylene (Teflon®) and expanded one (Gore-Tex®) and polyaramide (Kevlar®). No deterioration for polytetrafluoroethylene and polypropylene under irradiation was observed when materials were treated by physical means. Mechanical tests showed that all these materials could bear more than 50 N. Such a high tensile strength is never reached in visceral physiology. Results of graft elongation during tensile strength test shows two classes: a first one that includes high elongation grafts (Gore-Tex and Marlex) and a second one that includes low elongation grafts (Mersilene and Kevlar). As these materials have many potential uses ,in surgery, we have performed cytotoxicity tests. Material extracts were obtained under standardized conditions, and we have looked at a potentially toxic effect of substances eventually leached from the materials towards cells cultured in vitro. None of the material extracts listed above were cytotoxic except for untreated Kevlar. Toxicity disappeared when Kevlar was treated with methanol. As suspected, untreated Kevlar contains toxic additives introduced during the manufacture of this textile. Thus, in spite of good mechanical properties, Kevlar should not be used in pelvic surgery on account of its lower bicompatibility. These results shows that the choice of the grafts by surgeons must be relevant in a given application.
Keywords: biomaterials, irradiation, tensile strength, elongation, cytotoxicity
DOI: 10.3233/BME-1992-2404
Journal: Bio-Medical Materials and Engineering, vol. 2, no. 4, pp. 203-225, 1992
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl