Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jahed, Mahsaa; | Ghalichi, Farzana | Farhoudi, Mehdib
Affiliations: [a] Biomedical Engineering Department, Division of Biomechanics, Sahand University of Technology, Tabriz, Iran | [b] Neurosciences Research Center, Tabriz University of Medical Science, Tabriz, Iran
Correspondence: [*] Corresponding author. E-mail: mahsa.jahed.92@gmail.com
Abstract: BACKGROUND:The development of any disturbance in the Circle of Willis (COW) can change the hemodynamics of blood flow and result in damage to the vascular system. Clinical methods such as TCD for diagnosing an aneurysm or growth factors and rupture can measure blood velocity. Several factors influence the accuracy of TCD that can lead to wrong evaluations and affect the treatment planning. OBJECTIVE:In this study, the conformity between CFD and TCD was accomplished for investigating the accuracy of the clinical method (TCD) in different vessels of the Circle of Willis. METHODS:The realistic three-dimensional models have been produced from angiography images. Considering fluid-structure interaction, a domain of the blood flow and vessel wall has been simulated by the ANSYS.CFX software. The velocity in the cerebral arteries has been calculated and compared with the velocity acquired from TCD. RESULTS:According to the findings, there were significant differences between the results obtained from computational fluid dynamics and Doppler test in different vessels of the Circle of Willis. In some areas, differences close to 80 cm/s were also reported. CONCLUSION:According to the results, there are possibilities of errors in carrying out a Doppler test in some arteries and can lead to wrong estimates and ultimately incorrect decisions.
Keywords: Aneurysm, blood velocity, cerebral arteries, Transcranial Doppler, computational fluid dynamics
DOI: 10.3233/BME-191064
Journal: Bio-Medical Materials and Engineering, vol. 30, no. 4, pp. 427-438, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl