Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jahed, Mahsaa | Ghalichi, Farzana; * | Farhoudi, Mehdib
Affiliations: [a] Biomedical Engineering Department, Division of Biomechanics, Sahand University of Technology, Sahand New Town, Tabriz, Iran | [b] Neurosciences Research Center, Tabriz University of Medical Science, Tabriz, Iran
Correspondence: [*] Corresponding author. E-mail: fghalichi@sut.ac.ir.
Abstract: Background:Circle of Willis (COW) is a network of cerebral artery which continually supplies the brain with blood. Any disturbance in this supply will result in trauma or even death. One of these damages is known as brain Aneurysm. Clinical methods for diagnosing aneurysm can only measure blood velocity; while, in order to understand the causes of these occurrences it is necessary to have information about the amount of pressure and wall shear stress, which is possible through computational models. Objective:In this study purpose is achieving exact information of hemodynamic blood flow in COW with an aneurysm and investigation of effective factors on growth and rupture of aneurysm. Methods:Here, realistic three-dimensional models have been produced from angiography images. Considering fluid-structure interaction have been simulated by the ANSYS.CFX software. Results:Hemodynamic Studying of the COW and intra-aneurysm showed that the WSS and wall tension in the neck of aneurysms for case A are 129.5 Pa, and 12.2 kPa and for case B they are 53.3 Pa and 56.2 kPa, and more than their fundus, thus neck of aneurysm is prone to rupture. Conclusion:This study showed that the distribution of parameters was dependent on the geometry of the COW, and maximum values are seen in areas prone to aneurysm formation.
Keywords: Aneurysm, Circle of Willis, computational fluid dynamic, fluid-structure interaction
DOI: 10.3233/BME-181732
Journal: Bio-Medical Materials and Engineering, vol. 29, no. 3, pp. 357-368, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl