Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Review Article
Authors: Itoi, Eijia; * | Nagamoto, Hideakib | Sano, Hirotakac | Yamamoto, Nobuyukia | Kawakami, Juna
Affiliations: [a] Tohoku University School of Medicine, Sendai, Japan. E-mails: itoi-eiji@med.tohoku.ac.jp, koyomoe@med.tohoku.ac.jp, jun_gene@yahoo.co.jp | [b] Kurihara Central Hospital, Kurihara, Japan. E-mail: nagamoto@med.tohoku.ac.jp | [c] Sendai City Hospital, Sendai, Japan. E-mail: sanohirotaka@med.tohoku.ac.jp
Correspondence: [*] Corresponding author: Eiji Itoi, MD, PhD, Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan. Tel.: +81-22-717-7245; Fax: +81-22-717-7248; E-mail: itoi-eiji@med.tohoku.ac.jp.
Note: [1] This study was performed at the Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan.
Note: [2] A part of this article was read at the Symposium during 10th Biennial ISAKOS Congress, June 7–11, 2015, Lyon, France.
Abstract: The deadman theory is composed of two angles: θ1 and θ2, and it is recommended that both be less than or equal to 45°. Based on this theory, surgeons insert the anchor at 45°. However, the biomechanical studies show controversial data. We reviewed the original article and the biomechanical studies in the literature. We further performed three additional studies: 1) a finite element analysis to calculate the pullout strength of thread-less anchors inserted at 45°, 90°, and 135° to the polyurethane foam; 2) the same pullout test using thread-less anchors and the polyurethane foam; and 3) the same pullout test using metal threaded suture anchors and the simulated cortical bone. From the review and the additional studies, we came to the following explanations for the controversy: #1, the trigonometric calculation is not always applicable because of bone deformation; #2, insertion angle of 45° is the best for a thread-less anchor, but not for a threaded anchor; #3, θ1⩽45° is true, but it is not equivalent to inserting an anchor at 45°. In conclusion, insertion angle of 45° is the strongest for a thread-less anchor, but 90° is the strongest for a threaded anchor. The pullout strength depends on the inclination of the anchor, friction of the anchor–bone interface, and quality of the bone.
Keywords: Deadman theory, pullout strength, suture anchor, finite element model analysis, pullout test
DOI: 10.3233/BME-161586
Journal: Bio-Medical Materials and Engineering, vol. 27, no. 2-3, pp. 171-181, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl