Article type: Research Article
Authors: Liu, Hengquana; * | Li, Junfenga | Zhou, Shijiea | Long, Jiangpinga | Dong, Lihuab | Wei, Guixiangc
Affiliations: [a] College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu, China | [b] Department of Research & Development, Lifetech Scientific (Shenzhen) Co., Ltd, Shenzhen, China | [c] Department of Research & Development, Kinhely Bio-Tech Co., Ltd, Shenzhen, China
Correspondence: [*] Corresponding author: Hengquan Liu, PhD, College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu, China. Tel.: +86 28 84079074; E-mail: liuhengquan15@cdut.edu.cn.
Abstract: Surface modification is one approach to enhance the biocompatibility of implanted cardiovascular devices. In this work, a copper-containing film used to blood contacted biomaterials was prepared by vacuum arc deposition. The phase composition of the films was investigated via X-ray diffraction, and the adherence strength of the films was evaluated with conventional deformation tests. Blood compatibility of the films was characterized by hemolysis ratio, clotting time and platelet adhesion etc. The surface of inferior vena cava filters were smooth and uniform, no cracks or delaminations were observed on the deformed surface. These results indicate that the mechanical behavior of the films is suitable for withstanding deformation stresses as operation in clinic. Good blood compatibility of the copper-containing films was identified through experiment in vitro, the activated partial thromboplastin times (APTTs) of Cu/Ti films were similar to that of the uncoated substrate, and Cu/Ti films were also found to inhibit platelet adhesion comparing to the nitinol substrate. However, with increasing ratio of Cu/Ti, the hemolysis ratio increased, resulting in platelet damage. These results indicate that the copper-containing film has potential application on blood contacted devices.
Keywords: Copper-containing film, mechanical behavior, blood compatibility
DOI: 10.3233/BME-151547
Journal: Bio-Medical Materials and Engineering, vol. 26, no. 1-2, pp. 39-47, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl