Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kokubun, Ryoa | Wang, Weia; * | Zhu, Shenglib | Xie, Guoqiangb | Ichinose, Shizukoc | Itoh, Soichirod | Takakuda, Kazuoa
Affiliations: [a] Medical and Dental Device Technology Incubation Center, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan | [b] Institute for Materials Research, Tohoku University, Sendai, Japan | [c] Department of Instrumental Analysis Research Center, Tokyo Medical and Dental University, Tokyo, Japan | [d] Department of Orthopaedic Surgery, Kawakita General Hospital, Tokyo, Japan
Correspondence: [*] Corresponding author: Wei Wang, Medical and Dental Device Technology Incubation Center, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan. Tel./Fax: +81 3 5280 8044; E-mail: wangmech@tmd.ac.jp.
Abstract: Ti-based bulk metallic glasses are reported with high strength, low Young modulus and high corrosion resistance, suggesting their potentials in biomedical applications. However a thorough in vivo evaluation of its biocompatibilities has not been conducted yet. In this study, we implanted bars of Ti-based bulk metallic glass in the femoral bone of rats, followed up local tissue reaction as well as its component ions’ diffusion in local area and whole body. The Ti-based BMG (Ti40Zr10Cu34Pd14Sn2) alloy exhibited favorable features of both high strength and high elasticity. In vivo implant evaluation showed that it has a good tissue compatibility, equivalent bone integration and bonding ability with Ti sample. No component ion diffusion was detected up to 3 months post implantation. The possibility and efficacy of its use for bone implant is confirmed. Thus further long term implant study is recommended.
Keywords: Bulk metallic glass, Ti-based alloy, in vivo
DOI: 10.3233/BME-151546
Journal: Bio-Medical Materials and Engineering, vol. 26, no. 1-2, pp. 9-17, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl