Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Pathak, Saurabh | Shukla, S.K.; *
Affiliations: Center for Energy, Resources and Development (CERD), Mechanical Engineering Department, Indian Institute of Technology (BHU), Varanasi – 221005, India
Correspondence: [*] Corresponding Author. skshukla.mec@itbhu.ac.in
Abstract: A country like India has great potential for the conversion of waste heat into power through Organic Rankine Cycle (ORC). This paper focuses on the design feasibility of a method to produce combined power and cooling effect through ORC, which is environment friendly as it adds no emission for the environment. The organic fluid R123 has been selected for organic Rankine cycle. The working fluid R123 has very low ODP (ozone depletion potential of 0.02) and GWP (global warming potential of 77). The electrical power output and power output of expander are 5 kW and 5.26 kW respectively. The source temperature for ORC is 130. At the outlet of the evaporator the temperature of heat transfer fluid is 110. This available heat at the evaporator outlet act as heat input for diffusion absorption refrigeration (DAR) system. The working fluid for this system is selected as NH3-LiNO3-He, which operates at lower generator temperature. The evaporator temperature of DAR system is achieved around 5 also the cooling capacity produced around 2.5 kW. This combined system satisfies both cooling and power requirement simultaneously and make a system in uncoupled form. Further, the analysis of the efficiency of ORC system in variable condensing temperature has been done under Indian climatic conditions. The study reveals that with the increment in the ambient temperature condensing temperature increases. The performance of ORC degrades with the increment in condensing temperature. The cooling water from cooling tower passes from the evaporator of DAR system. This leads to decrease in the cooling water temperature from 23.5 to 15.5. The condensing temperature decreases from 35 to 32 due to the temperature reduction of cooling water. In turn, the efficiency of ORC system increases by approximately 7%. This combined system meets the demand of both power production and cooling effect with no emission of pollutants to the environment.
Keywords: Thermal efficiency, organic Rankine cycle, condenser, diffusion absorption chiller
DOI: 10.3233/AJW190017
Journal: Asian Journal of Water, Environment and Pollution, vol. 16, no. 2, pp. 35-42, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl