Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Motherby, Helma; | Pomjanski, Natalia | Kube, Mary | Boros, Alexandra | Heiden, Thomas | Tribukait, Bernhard | Böcking, Alfred
Affiliations: Institute of Cytopathology, Heinrich‐Heine‐University, Moorenstr. 5, D‐40225 Düsseldorf, Germany | Department of Medical Radiobiology, Karolinska Institute, S‐10401 Stockholm, Sweden
Note: [] Corresponding author: Prof. Dr. Alfred Böcking, Institute of Cytopathology, Heinrich‐Heine‐University Düsseldorf, Moorenstr. 5, D‐40225 Düsseldorf, Germany. Tel.: +49 211 81 18346; Fax: +49 211 81 18402; E‐mail: boecking@uni‐duesseldorf.de.
Abstract: Aims: To determine the sensitivity and specificity of flow‐ and image‐cytometry for the detection of DNA‐aneuploidy as a marker for malignant cells in effusions. Methods: 200 effusions (80 tumor cell‐positive, 74 negative and 46 cytologically equivocal) were stained with DAPI‐SR for DNA‐flow‐ and with Feulgen‐Pararosaniline for ‐image‐cytometry. They were measured using a PAS‐flow‐cytometer and an AutoCyte‐QUIC‐DNA‐workstation according to the ESACP consensus reports for DNA‐flow‐ and ‐image‐cytometry, respectively [7,23,29,49]. Results: Sensitivity of DNA‐aneuploidy for the identification of malignant cells was 32.1% for DNA‐flow‐ and 75.0% for ‐image‐cytometry, specificity of ‐euploidy in benign cells was 100.0% for both methods. Positive predictive value of DNA‐aneuploidy for the identification of malignant cells was 100.0% for both techniques, negative predictive value of DNA‐euploidy was 48.6% for DNA‐flow‐ and 72.0% for ‐image‐cytometry. Conclusions: Searching for DNA‐aneuploidy as a diagnostic marker for neoplastic cells in serous effusions image‐cytometry revealed superior sensitivity as compared with monoparametric flow cytometry.
Keywords: DNA‐flow‐cytometry, DNA‐image‐cytometry, serous effusion, cytopathology
Journal: Analytical Cellular Pathology, vol. 24, no. 1, pp. 5-15, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl