Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kayser, K.; | Kayser, G. | Becker, H.D. | Herth, F.
Affiliations: Department of Pathology, Thoraxklinik, Heidelberg, Germany | Department of Endoscopy, Thoraxklinik, Heidelberg, Germany
Note: [] Corresponding author: Klaus Kayser, MD, PhD, Department of Pathology, Thoraxklinik, Amalienstr. 5, D‐69126 Heidelberg, Germany. Tel.: +49 6221 396496; Fax: +49 6221 396238; E‐mail: klkayser@lung.de.
Abstract: Aim: To analyze the diagnostic accuracy of telediagnostic procedures for transbronchial fine needle aspirations. Material and methods: A double blind study was performed on cytological slides of 54 randomly selected cases with transbronchial fine needle aspirations. The slides were digitized using a Leica digital camera DC100 mounted on a microscope Leica Laborlux S, and analyzed by an experienced pathologist without knowing the definite diagnosis or any additional clinical data. The diagnoses stated by analyzing the digital images were compared to the final conventional diagnoses. In addition, the duration of the digital diagnosis, used magnifications, and difficulties for correct sampling were documented. Results: The “digital” diagnoses of the 54 cases were all in general agreement with the definite diagnoses. No wrong positive or wrong negative case in respect to malignant/non‐malignant (31/23) or to small cell/non‐small cell (9/22) occurred. The performance of a digital diagnosis lasted for 115 s at average (15–260 s), and is significantly longer compared to that of conventional fine needle aspiration judgement (20 s). The screening magnification was commonly set to ×2.5, that for definite diagnostic analysis ×40. Benign diseases (2 tuberculosis and 3 sarcoidosis cases) were correctly classified. Conclusions: Telepathology systems can probably be used for fine needle aspiration analysis without major diagnostic errors. Their use can improve the endoscopic sampling and avoid second anesthesia when missing the lesion of request during the first examination.
Keywords: Fine needle aspiration, lung, telepathology, feasibility study
Journal: Analytical Cellular Pathology, vol. 21, no. 3-4, pp. 207-212, 2000
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl